Aluminum block bath
Dry thermo unit

DTU-1BN
Product Code:0075929-000

Temperature accuracy as water bath, affordable deep type. B type for up to +110ºC.


Aluminum block is option

Main Application

Various enzyme reaction and heat denaturation of DNA/RNA
Hydrolysis reaction of sugar, protein and fatty acid

Features

Deep block for afford centrifuge tubes and test tubes

DTU-1BN holds one of specialized deep block which can hold 9 of 50ml disposable centrifuge tubes.

B (bio) type is for up to +110ºC

Can be used for heat denaturation of nucleotide and test for enzyme reaction.

Meet to various containers with exchanging block

We have a several deep blocks (option) to meet with various containers.

DTU-1BN has simple OFF timer and buzzer timer.

DTU-1BN has simple ON timer, OFF timer and buzzer timer.

Temperature accuracy as water bath

With sensor block system (PAT.P), it can control temperature accurately as water bath which is not achieved by conventional aluminum block bath.

Condense with spraying nitrogen gas

With evaporation head (option), condensing sample by removing solvent is possible.


Specifications

ModelDTU-1BN
Temperature Range RT +5 ºC - +110 ºC
Temp. Control Accuracy Below ±0.1 ºC
Minimum temperature setting unit 0.1 ºC
Temperature setting UP/DOWN key
Temperature Display Digital display (setting temperature and current temperature)
Memory Three temperature settings
Heater 100W
Timer ON timer (1min - 99hr59min)
OFF timer (1min - 99hr59min)
BUZZER timer (1min - 99hr59min)
Safety device / function Sensor error, high/low temperature, memory error, auto tuning error, fuse, thermostat
Dimensions 210 x 318 x 130Hmm
Weight Approx. 4kg
Power Supply AC100V 1.3A
Standard Accessory Hook handle for taking block out x 1, fuse (2A) x 1

Dimensions

Options

Deep block for micro tube  AL-0836

For DTU-1B/2B/1C/2C (micro tube 0.5ml x 36)

Deep block for micro tube  AL-1136

For DTU-1B/2B/1C/2C (micro tube 1.5ml x 36)

Deep block for micro tube  AL-1136B

For DTU-1B/2B/1C/2C (micro tube 2.0ml x 36)

Deep block for test tube  AL-1236

For DTU-1B/2B/1C/2C (test tubeφ12mm x 36)

Deep block for test tube  AL-1336

For DTU-1B/2B/1C/2C (test tube φ13mm x 36)

Deep block for test tube  AL-1525

For DTU-1B/2B/1C/2C (test tube φ15mm x 25)

Deep block for disposab ...  AL-1616F

For DTU-1B/2B/1C/2C (Centrifuge tube 15ml x 16)

Deep block for test tube  AL-1625

For DTU-1B/2B/1C/2C (test tube φ16.5mm x 25)

Deep block for test tube  AL-1820

For DTU-1B/2B/1C/2C (test tube φ18mm x 20)

Deep block for test tube  AL-2116

For DTU-1B/2B/1C/2C (test tube φ21mm x 16)

Deep block for test tube  AL-2412

For DTU-1B/2B/1C/2C (test tube φ24mm x 12)

Deep block for test tube  AL-2512

For DTU-1B/2B/1C/2C (test tube φ25mm x 12)

Deep block for disposab ...  AL-2909F

For DTU-1B/2B/1C/2C (centrifuge tube 50ml x 9)

Deep block for test tube  AL-3009

For DTU-1B/2B/1C/2C (test tube φ30mm x 9)

Deep block for test tube  AL-3505

For DTU-1B/2B/1C/2C (test tube φ35mm x 5)

Deep block for disposab ...  AL-5011F

For DTU-1B/2B/1C/2C (centrifuge tube 15ml x 8 + 50ml x 3)

Deep block for micro tube  AL-8136

For DTU-1B/2B/1C/2C (micro tube 0.5ml x 18 + 1.5ml x 18)

Related Products

Aluminum block bath  Cool thermo unit  CTU-Mini

Compact setting area which doesn’t occupy bench space. Quick temperature transition, a ...

Aluminum block bath  Cool thermo unit  CTU-Neo

Applicable to isothermal gene amplification by programming. Quick temperature transit ...

Aluminum block bath  Dry thermo unit  DTU-1CN

Temperature accuracy as water bath, affordable deep type. C type for up to +200ºC.

Aluminum block bath  Dry thermo unit  DTU-2BN

Temperature accuracy as water bath, affordable deep type. B type for up to +110ºC.

Aluminum block bath  Dry thermo unit  DTU-2CN

Temperature accuracy as water bath, affordable deep type. C type for up to +200ºC.

Aluminum block bath  Dry thermo unit  DTU-Mini

Compact setting area which doesn’t occupy bench space. Quick temperature transition, ...

Aluminum block bath  Dry thermo unit  DTU-Neo

Applicable to isothermal gene amplification by programming. Quick temperature transiti ...

Nitrogen gas spray unit ...  Evaporation head  EN1-12

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.

Nitrogen gas spray unit ...  Evaporation head  EN1-16

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.

Nitrogen gas spray unit ...  Evaporation head  EN1-20

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.

Nitrogen gas spray unit ...  Evaporation head  EN1-25

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.

Nitrogen gas spray unit ...  Evaporation head  EN1-36

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.

Nitrogen gas spray unit ...  Evaporation head  EN1-5

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.

Nitrogen gas spray unit ...  Evaporation head  EN1-9

For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.


home products faq about_us inquiry