Non-invasive turbidity meter for culturing by rotary shaker.

OD-MonitorA&S
Product Code:

Measuring OD untouched flasks while cultivating as usual!!


OD-MonitorA&S
(Image of 2sets of ODSensor-S connection)

Main Application

Cell density observation of bacterial in culturing
Cell density observation of pathogenic bacteria
Cell observation of bacillus in culturing under anaerobic conditions which gas concentration is important
Cell density observation of bacteria with slow multiplication rate
Cell density observation of floating mammals cell (scheduled)

Features

Saving of the turbidity measurement in culture with reasonable price

It automatically and untouched measure turbidity of rotating culture, such as coliform bacillus, in 100/200/300/500ml glass Erlenmeyer flask (volume is 1/5 amount ±10%, no Sakaguchi and no baffle).

Used with the shaker (rotating type)

It is used with incubator shaker BR series or double shaker NR series.
(The shaker of the other companies cannot be used) .
Install the measurement unit to rack only.

Image of conbination with BR-43FL

Image of conbination with BR-180LF

Image of conbination with NR-3



Eight channels in maximum, The measurement value is converted to OD600 of the spectrophotometer.

It measure 8ch in maximum at the same time.
The measurement value is converted into 600 nm of the spectrophotometer (our BPM-10Bio).
It is possible to correct gap from the spectrophotometer.


It alarms you when reached set OD by buzzer.

The control unit displays the present value and target value.
When exceeding target value, it is possible to alarm by buzzer.

Data is saved to USB memory.

Data is saved by text format to the flash memory of USB2.0 (some is not used).
The edit with spreadsheet is possible.


Specifications and product configurations of this set

ModelOD-MonitorA&S
Component Unit Control unit :ODBox-A
Measurement unit :ODSensor-S
Temperature range of measurement +15ºC - +50ºC(Be careful of setting temperature of bio shaker.)
Applied Erlenmeyer flask and volume 100/200/300/500ml flask made transparent glasses (no colored and no baffle), 1/5 volume±10% (*)
Shaking Method Rotating (It should shake on either of following conditions.)
Shaking speed and shaking amplitude 80 - 400rpm (Amplitude25mm)
80 - 200rpm (Amplitude30/40mm)
80 - 250rpm (Amplitude50mm) (*)
* A set unit of shaking speed is 10rpm.
(*) Set with ODBox-A at the beginning of measurement OD-Monitor is can be used only with TAITEC's incubator shaker BR series or double (rotary) shaker NR series (both are producing ). Be sure to check shaking amplitude when you measure and ground of ODBox-A and shaker for reducing electric noise.

Specifications of each product to configure this set

ModelODBox-A
Display of (OD) value Display of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria
Measurement Range 0.1 - 2.0(accuracy guarantee range 0.5 - 1.5)
Correction for biological species other than E. coli bacteria and gap from spectrophotometer Enter correction factors (0.01 - 2.55、initial value is 1.00)
Correction allowance / Correction range Within 15% (OD = 0.5 - 1.5)
Interval 1/5/10/30/60/120/240min
Maximum Measurement Time Internal memory : 360 points (*1)
USB memory : Up to USB memory
Maximum Connectable ODSensor-S 8sets(2ch x 4), Measurement under all same conditions
Interface for print output RS-232C (*2)
Interface for external storage medium Port for USB2.0 flash memory (*3)
Other Functions Alarm function (alarm by buzzer at reached target OD) (*4)
Dimensions 153 x 220 x 127Hmm
Standard Accessory Flat cable (2m) x 1
(*1)Point = Total measurement time / Interval. The 360th point figure is to updated when it exceed 360 points.
(*2)The recommended cable is KRS-433XF07K made by SANWA SUPPLY and the recommended rollpaper printer is BL2-58NBJC made by SANEI DENKI corporation.
(*3)Some memory cannot be used with this unit even if it can be used with a personal computer.
(*4)If it reaches the target value, a buzzer may not immediately ring depending on setting of interval.
ODSensor-S is sold separately.

ModelODSensor-S
Measurement Method Infrared rays penetration light method (horizontal projection)
Measurement Wavelength 950nm
Connection One set (use attached 0.5m flat cable )
Power Supply Supplied from ODBox-A (option)
Standard Accessory Flask pad large, small x each 1,Screw for installation (M4x15mm) x 6, Cable clip large x 2 + small x 4, Flat cable (0.5m) x 1
(*)Large is for 300ml and small is for 100/200ml. The pad for 500ml is attached to clamp CF-0500.
ODBox-A, Clamp is sold separately.

Options

Clamp   CF-0100

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Clamp   CF-0200

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Clamp   CF-0300

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Clamp   CF-0500

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Universal shaking rack  MT-2925

It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.

Universal shaking rack  MT-4030

It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.

Color cap & tag  OD-CAP0408

Cable tag for identifying each sensor

Flat cable(2m)  OD-CAV0200

Connecting cable between ODBox and ODSensor

Related Products

Large size constant tem ...  Bioshaker  BR-180LF

Split doors enables easier access to large container. Movable with wheels.

Small size constant tem ...  Bioshaker  BR-22FH MR

Small type of combined usability and space-saving

Small size constant tem ...  Bioshaker  BR-22FP MR

Small type of combined usability and space-saving Those which have cooling system are ...

Small size constant tem ...  Bioshaker  BR-22UM MR

Small type of combined usability and space-saving

Small size constant tem ...  Bioshaker  BR-23FH MR

Small type of combined usability and space-saving

Small size constant tem ...  Bioshaker   BR-23FP MR

Small type of combined usability and space-saving Those which have cooling system are ...

Small size constant tem ...  Bioshaker  BR-23UM MR

Small type of combined usability and space-saving

Large size constant tem ...  Bioshaker  BR-300

Long selling large type with variable shaking amplitude.

Large size constant tem ...  Bioshaker  BR-3000LF

Largest capacity in the series, variable shaking amplitude.

Large size constant tem ...  Bioshaker  BR-300LF

Long selling large type with variable shaking amplitude.

Medium size constant te ...  Bioshaker  BR-40LF

Well achieved middle size. Long selling clear hood type. Space saving by stacking.

Medium size constant te ...  Bioshaker   BR-42FL MR

Well achieved middle size. Left-right opening door type. Both are space saving by stac ...

Medium size constant te ...  Bioshaker  BR-42FM MR

Well achieved middle size. Left-right opening door type. Both are space saving by stac ...

Medium size constant te ...  Bioshaker   BR-43FH MR

Well achieved middle size. Left-right opening door type. Both are space saving by stac ...

Medium size constant te ...  Bioshaker  BR-43FL MR

Well achieved middle size. Left-right opening door type. Both are space saving by stac ...

Medium size constant te ...  Bioshaker  BR-43FM MR

Well achieved middle size. Left-right opening door type. Both are space saving by stac ...

Large size constant tem ...  Bioshaker   GBR-200

Save your space with lift-up door and stackable, enable to use as laboratory table, ...

Large size constant tem ...  Bioshaker  GBR-300

Save your space with lift-up door and stackable, enable to use as laboratory table, cu ...

Large size shaker  Double shaker  NR-150

Long selling large shaker with large capacity. According to container or application ...

Small size shaker  Rotary shaker  NR-2

Long selling small shaker easy operation inside constant temperature chamber. NR-2 su ...

Medium size shaker  Rotary shaker  NR-20

Long selling medium shaker with sufficient capacity. NR-20 suitable for mainly Erlenm ...

Small size shaker  Double shaker  NR-3

Long selling small shaker easy operation inside constant temperature chamber. NR-3 ca ...

Medium size shaker  Double shaker  NR-30

Long selling medium shaker with sufficient capacity. NR-30 can perfume both reciproca ...

Medium size shaker  Triple shaker  NR-80

Long selling medium shaker with sufficient capacity. NR-80 can shake with letter 8 fi ...

Non-invasive turbidity ...    OD-MonitorB&L

New line up for OD-Monitor measurable OD while cultured as usual! It is for large Erle ...


home products faq about_us inquiry