e-TAITEC.com

Product Info

Digital colorimeter

Easy operation OD Monitor miniphoto518R

Code No.: 0040889-000

Can measure the absorbance (turbidity) just by inserting Test tubes and L-shaped test tubes used in cultivation and reaction. Wavelength can be changed with replacement of filter.

Light shielding cap (Standard accesorie) and Printer (Option) in combination.

Applications

Measurement turbidity of Microbe culture fluid
Absorbance measurement of Colorimetric samples
Applications requiring measuring Absorbance/Transmittance of sample

Features

•For φ16.5 to 18 mm Test tubes and L-shaped test tubes, Liquid volume 4 mL
•Comes with 660 nm Glass filter (Changes wavelength by replacement)
•Displays the value just by inserting the test tube
The display can be pinned with the HOLD key
Measurement by inserting Test tube that has been used
in cultivation and reaction


Minimum volume of the measurement is 4 mL.
Minimum volume of the measurement is 4mL .

Measurement results can also be recorded with a data logger
When combined with a data logger, daily measurements can be time-stamped and recorded on an SD card without the use of a PC.

Specifications

Modelminiphoto518R
Measurement rangeAbsorbance: 0.000 to 2.000 A,
Transmittance: 1 to 100%T
Measurement wavelength660 nm (*1)
Vesselsφ16.5 to 18 mm Glass test tube or L-shaped test tube (*2)
Light source/DetectorHigh-Brightness LED, Photodiode
DisplayOptical Density/Transmittance simultaneously, HOLD function.
InterfacePrinter (Optional)
Dimensions (W x D x H)187 x 106 x 95mm
WeightApprox. 880 g
Power supplyAC100 V
Standard accessoriesGlass filter (660 nm) ×1 pc, Light shielding cap ×1 pc (*3), AC adapter ×1 pc
(*1)Wavelength can be changed with replacement of the filter. See the below option for details.
(*2)Test tubes without scratches should be used. Ask us when a different diameter of Test tube is required.
(*3)It cannot be used with L shaped test tube. Aluminum foil or something can be substituted if light shielding is required.

Dimensions

Accessories

Interference Filter | Interference Filter R420nm
Band-pass filter approx. 10mm FWHM, R420nm, Dedicated for miniphoto 518R.
■: ■:
Interference Filter | Interference Filter R530nm
Band-pass filter approx. 10mm FWHM, R530nm, Dedicated for miniphoto 518R.
■: ■:
Interference Filter | Interference Filter R620nm
Band-pass filter approx. 10mm FWHM, R620nm, Dedicated for miniphoto 518R.
■: ■:
Interference Filter | Interference Filter R660nm
Band-pass filter approx. 10mm FWHM, R660nm, Dedicated for miniphoto 518R.
■: ■:
Printer | Printer for miniphoto518R
Printer for miniphoto518R
■: ■:
Translate »