e-TAITEC.com

Product Info

Chiller for open circuit

Coolnit CL-151

Code No.:

Long-selling, open circuit chiller with high precise temperature control Redesigned to be more user-friendly and much lighter.For temperature control of constant temperature water baths and analytical instruments.

Long-selling, open circuit chiller with high precise temperature control Redesigned to be more user-friendly and much lighter For temperature control of constant temperature water baths and analytical instruments.
Closed circuit is also available as an option.


Down Load(Useful Information)

CL-81/151/601 catalog

Features

Air-cooled, precision temperature control, and long
selling chillers for open circuits. Renewal improves
detailed usability. 

CL series is an air-cooled, high-precision open-circuit chiller (constant temperature water circulation system).
It is mainly used for temperature control of constant temperature water baths, and is ideal for circulation to temperature control water baths required for quality tests, etc.
This series is a long-selling product that has been refined for over 35 years.
CL-81/151/601 is reliable as in the previous model and their weight were reduced by 3kg/7kg/1kg each. In addition, the drain cock was repositioned from the rear side of the unit to the front side for better usability.
Temperature recording and safety device output are
possible, and optional program control are possible

The CL series allows for temperature recording and safety device operation signal output, and external temperature sensors can be used.
Also, by connecting to a program setting device (sold separately), temperature and time program control are possible.
Optional port tank allows for circulation in closed circuits
In addition to circulation to the water bath as a chiller for the open circuit, it can also circulate to equipment (= closed-circuit circulation) using a separately sold port tank.
Even for the one targets with high piping resistance such as rotary evaporators, circulation can be easily started with the
built-in priming pump.

Specifications

ModelCL-151
Operating environmental temp. range(*1)+5℃〜+30℃
Operating temperature range-10℃〜+70℃(*2)
Temperature control accuracy〜±0.3℃ (*3)(*4)
Cooling capacityApprox. 270W
Compressor (air-cooled) output150W
Pumping capacity(50/60Hz)Max. flow rate: 7L/min
Max. lift height:4m (at 3L/min, both 50/60Hz)
Temperature displayDigital (PV/SV independent display/ PV display in 0.01°C unit)
Flow displayDigital display
Heater600W
Circulation nozzle diameterOuter diameter φ13 mm
Safety device/Safety functionEarth leakage/overcurrent breaker, Flow low limit error, High/Low temperature safety device, Anti-freezing safety device
Other FunctionsRemote temperature setting, Temperature recording output, Safety device operation signal external output, External temperature sensor connection, RS-485ModBus communication
External Dimensions252×429×478Hmm
WeightApprox. 28kg
Power supplyAC100V・13.5A
Standard accessoriesInsulated circulation hose(1m) × 2, hose band × 2
(*1)Make sure there is no condensation on the unit
(*2)Use a low-temperature heating medium when using the product at a temperature of 7°C or less. (Contact us for details.) Pure water and distilled water cannot be used.
(*3)The temperature accuracy is when the inside of the water bath is sufficiently stirred. The temperature accuracy and power consumption vary depending on various conditions, such as the set temperature, environmental temperature, water bath capacity, and stirring state. We recommend using a lid for the water bath. The specifications of this unit include the performance values according to our specified measurement method
(*4)Temperature control accuracy at 25.0°C setting is ~ ±0.1°C using environmental temperature 25°C/clean water 5L/heat insulation water bath/lid
(*5)Capacity when the environmental temperature is 25°C and the circulating fluid is +10°C, and 50Hz. The cooling capacity will be reduced in environments exceeding 30°C.

Dimensions

Accessories

| Port tank
For CP-80R/150R CL-80R/150R for open circuit
■: ■:
| Stainless steel thermal insulation water bath A-type φ13mm
Inner Dimension 300×400×200H mm, With nozzle (ex.dia.φ13 mm)
■Inner Dimension:300×400×200Hmm ■:
| Stainless steel thermal insulation water bath A-type φ22mm
Inner Dimension 300×400×200H mm, With nozzle (ex.dia.φ22 mm), CL-600N: Available Circulation to closed circuit machine.
■Inner dimension:300×400×200Hmm ■:
PVC water bath type D, φ13mm | PVC thermal insulation water bath type D φ13 mm
Inner Dimension 164×294×150H mm, With nozzle (ex.dia.φ13 mm)
■Inner Dimension:164×294×150Hmm ■Nozzle:External d ...
| Spring net rack B2-type
External dimensions 270×320×140H mm
■External dimensions:270×320×140Hmm ■Applicable Mo ...
| Spring net rack C-type
External dimensions140×240×140H mm
■External dimensions:140×240×140Hmm ■Applicable Mo ...
| Caster
Set of 4, CP-80R/150R CL-80R/150R
■Qty:Set of 4 ■Applicable Models: CP-80R/150R, CL- ...
Antifreeze | Show Brine Blue
Use when needed together with low temperature water bath unit or immersion cooler, use when setting below +7℃
■Weight:20kg, 1 can ■:

Related Products

Program setting Device | Program unit | PU-5N
Combination with Shaking Water bath enables temperature control and auto ON-OFF shaking.
■Pattern memory (Temperature programming):16 ■Segment memory (Temperature programming):16segment/ pattern
Program setting Device | Program unit | PU-6N
Enables Temperature transition and Program operation of Shaking ON/OFF with our Water baths, Incubator shaker, and Chillers for Open circuit in combination.
■Number of Storage pattern (Temperature program):16 ■Number of Storage segment(Temperature program):16 segments/patterns
Chiller for open circuit | Coolnit | CL-81
Long-selling, open circuit chiller with high precise temperature control Redesigned to be more user-friendly and much lighter.For temperature control of constant temperature water baths and analytical instruments.
■Operating environmental temp. range(*1):+5℃〜+30℃ ■Operating temperature range:-10℃〜+70℃(*2)
Chiller for open circuit | Coolnit | CL-601
Long-selling, open circuit chiller with high precise temperature control Redesigned to be more user-friendly and much lighter.For temperature control of constant temperature water baths and analytical instruments.
■Operating environmental temp. range(*1):+5℃〜+30℃ ■Operating temperature range:-15℃ 〜 +70℃(*2)(*3)