e-TAITEC.com

Product Info

Constant temperature incuvator shaker with NewMax drive

MaxMixer EVR-032

Code No.: 0079863-000

Vibratory mixing with a well plates and microtubes. The “NewMax drive” ensures strong, silent, uniform mixing operation.

Image of using two 1.5mL microtube racks (option)

Applications

Mixing of 96 well plates, deep well plates, microtubes
Dissolving and mixing of reagents
Formulation of high-viscosity liquids
Solubility testing of substances that are almost insoluble

Features

Offering stable, uniform shaking results: What is “NewMax drive”?

Shaking machines are subject to random, unforeseeable moves synergistically caused by vibrations from within and from the horizontal and vertical path displacement of the shaking table (container platform). These unwanted factors can reduce the basic shaking effect of the machine.
TAITEC’s newly adopted “NewMax drive,” based on TAITEC’s proprietary technology, offers consistent, uniform shaking results.
Compliance with validation requirements (IQ/OQ)
Drug manufacturers are required to validate the devices they use as part of GLP/GMP requirements. The DWMax Series is designed to deal with such IQ/OQ needs.
Energy-efficient and extremely silent
Highly energy-efficient, the DWMax Series is designed to meet the energy-saving needs of laboratories seeking to cut the power consumption of each device used. In addition, TAITEC’s sound-reducing technology lessens noise emissions in a laboratory environment.

Specifications

ModelEVR-032
Shaking MethodHorizontal eccentric vibration
Shaking Speed200 - 1600rpm
Applicable Container / Numberwell plates x 2 or microtube racks (option) x 2
Surroundings temperature+5°C to +35°C
Shaking speed displayDigital, up-down setting
Memory functionSingle setting for both temperature and velocity
Safety device / functionFuse, overload protection, overvoltage protection
Dimensions302 x 365 x 100Hmm
WeightApprox. 7kg
Power SupplyAC100V, 0.5A
●The EVR-034 and EVR-032 are designed to conform to 96-well well plates. For this reason, different well sizes, such as 24-well and 384-well types, may produce different shaking results.
●Microtube racks are options.

Dimensions

Accessories

Microtube Rack | EM-0524
Alminum microtube rack for 24 pcs of 0.5ml microtube
■Applicable Container / Number:24 tubes (0.5ml) ■M ...
Microtube Rack | EM-1524
Alminum microtube rack for 24 pcs of 1.5ml microtube
■Applicable Container / Number:24 tubes (0.5ml/2.0 ...
Microtube Rack | EM-1515
Alminum microtube rack for 12 pcs of 5ml tube
■Applicable Container / Number:5mL tube × 12 ■Mate ...

Related Products

Constant temperature incubator shaker with NewMax drive | DWMax | MBR-032
Agitation and heating of well plates and microtubes. The “NewMax drive” enables high culturing efficiency through uniform agitation.
■Temperature Range:Room temperature +7°C to +60°C ■Temp. Control Accuracy:±0.5°C to +1.0°C (*1)
Constant temperature incubator shaker with NewMax drive | DWMax | MBR-032P
Agitation and cooling/heating of well plates and microtubes. The “NewMax drive” enables high culturing efficiency through uniform agitation.
■Temperature Range:+15°C to +60°C (*1) ■Temp. Control Accuracy:±0.5°C to +1.0°C (*2)
Constant temperature incubator shaker with NewMax drive | DWMax | MBR-034
Agitation and heating of well plates and microtubes. The “NewMax drive” enables high culturing efficiency through uniform agitation.
■Temperature Range:Room temperature +7°C to +60°C ■Temp. Control Accuracy:±0.5°C to +1.0°C (*1)
Constant temperature incubator shaker with NewMax drive | DWMax | MBR-034P
Agitation and cooling/heating of well plates and microtubes. The “NewMax drive” enables high culturing efficiency through uniform agitation.
■Temperature Range:Room temperature -7°C to +60°C (*1) ■Temp. Control Accuracy:±0.5°C to +1.0°C (*2)
Constant temperature incubator shaker with NewMax drive | DWMax | VBR-104
Our proprietary technology "NewMax drive" enables excellent aeration effectiveness Max. 500r/min. Optimum for bacteriophage culture and small-scale cultivation.
■Temperature range (*1):8℃ above RT (*2) to 60℃ ■Temp. control accuracy (*3):±0.5℃ to ±1.0℃
Constant temperature incuvator shaker with NewMax drive | MaxMixer | EVR-034
Vibratory mixing with a well plates and microtubes. The “NewMax drive” ensures strong, silent, uniform mixing operation.
■Shaking Method:Horizontal eccentric vibration ■Shaking Speed:200 - 1600rpm
Constant temperature incuvator shaker with NewMax drive | MaxMixer | EVR-104
Vibratory mixing with microtubes and centrifuge tubes. The “NewMax drive” ensures strong, silent, uniform mixing operation.
■Shaking Method:Gyratory shaking ■Shaking Speed:50 - 500rpm
Shakers for Well plates and Microtubes | Micro mixer | E-36
Effective mix of 96 well plates and microtubes. Shaking speed is switchable between high and low.
■Shaking Method:horizontal excentric vibration ■Shaking Speed:Switch range:300 - 1000rpm (LOW RANGE)1200 - 2500rpm (HIGH RANGE)
Translate »