Product Info
Shaking water bath
Water bath shaker MM-10N
Code No.: 0089994-000
A Shaking Water bath with high temperature accuracy. It has been renewed to improve usability and comes standard with programmable functions.
Applications
●Cultivation of Microbe such as E. coli●Various incubations such as Enzyme reaction
Down Load(Useful Information)
MM-10N_ML-10N_FlyerFeatures
A long-selling unit has been renewed to improve usability.The operation panel has been completely redesigned, and programming functions are now included as standard.
The MM-10N is the successor to the MM-10, which we have been selling for about 30 years.The control panel has been completely redesigned, and the shaking speed setting has been changed from the previous model, which was set by a dial, to a digital setting and display of both temperature and speed using up and down keys.
Programmable operation is now possible. The set of “temperature, shaking speed, and time” can be programmed up to 9 steps.
Furthermore, to make the drainage process easier, the drainage drain port has been moved from the right side of the previous model to the front, and other fine improvements have been made to usability.
Reciprocating shaking, shaking width in the range of 10 to 40 mm. Monod shaking also available as an option
The temperature, shaking speed, and shaking width can be adjusted to suit a variety of tests. A spring net shaking platform is included, on which vessels such as Erlenmeyer flasks and test tubes can be placed. If a stronger fixation of the vessel is required, please use the optional clamp.An optional monod kit for shaking L-shaped test tubes is also available.
The shaking platform is designed to be easily attached and detached from the main unit for easy cleaning.
Application in Ames (mutagenicity) test
The MM-10N has a temperature control accuracy of ±0.1°C, making it possible to pre-cultivate test strains that meet GLP standards (maintaining a temperature of +37°C with an accuracy of within ±0.5°C). (We recommend using a roof lid to reduce evaporation inside the tank and maintain temperature accuracy.)Specifications
Model | MM-10N |
---|---|
Operating Environment Temperature Range(*1,2) | +5℃ to +35℃ |
Operating temperature range (*2,3) | Room temperature +5°C to +80°C |
Temperature control accuracy(*4) | 〜±0.1℃ |
Shaking method | Reciprocal shaking |
Shaking speed | 30 to 160r/min |
Shaking width | 10 to 40mm (Stepless variable) |
Temperature/speed setting and display | Digital setting, digital display |
Heating/cooling method | Heating: heater (1300W),No cooling function |
Stirring method in Bath | Jet flow |
Program function | 1 program, 9 steps, temperature/speed/time can be set for each step (up to 99h59min), temperature gradient function available |
Safety devices/Safety functions | Earth leakage/overcurrent breaker, Fuse, High temperature safety device, Dry-heating protection with float, Temperature sensor abnormality diagnosis, Motor abnormality, Speed limiter, Non- volatile memory abnormality, Output abnormality Overload relay (ML-10N only), Heater cover, Sample protection safety device |
Shaking platform dimensions(*5) | 400×300×125Hmm |
Water bath internal dimensions/capacity | 520×365×225Hmm、approx. 24L(when water level is 100mm from the bottom plate of the shaking platform) |
External dimensions/weight | 810×476×316Hmm、approx. 46kg |
Power supply | AC100V・15A |
Standard accessories | Dedicated spring net shaking platform x 1 pc, Drain hole filter x 1 pc |
(*1)No condensation. | |
(*2)When using the ML-10N at an ambient temperature of 30°C or higher, in an installation location where heat exhaust is prevented, or when the supply voltage is low, the cooling capacity may decrease, and the set temperature may not be reached. | |
(*3)When using below +7°C, use antifreeze, and when using above +70°C, use a high-temperature heat medium. Please check our website for information on each heat medium specified by our company. | |
(*4)The temperature accuracy is based on the case where clean water is used and the water bath is sufficiently stirred. Temperature accuracy varies depending on various conditions such as ambient temperature, set temperature, how the vessel is installed, and water volume. The specifications of this unit are performance values based on the measurement method specified by our company. If you would like validation of temperature accuracy, etc., please contact us. | |
(*5)The inner dimensions of the shaking table are 370 x 270 mm. The height is measured from the bottom of the shaking platform to the top of the upper spring net frame. The height of the spring net can be changed in 15 mm increments. | |
●External output (temperature/speed/safety device activation signal output) is also available by special order. Please contact us for details. |
Dimensions
Accessories
Clamp | CF-0050
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:50ml Erlenmeyer flask ■:
Clamp | CF-0100
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:100ml Erlenmeyer flask ■:
Clamp | CF-0200
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:200ml Erlenmeyer flask ■:
Clamp | CF-0250
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:250ml Erlenmeyer flask ■:
Clamp | CF-0300
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:300ml Erlenmeyer flask ■Sta ...
Clamp | CF-0500
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:500ml Erlenmeyer flask ■Sta ...
Clamp | CF-1000
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:1L Erlenmeyer flask ■Standa ...
Clamp | CF-2000
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack■Application Container:2L Erlenmeyer flask ■Standa ...
Clamp | SF-0500
Parts to fix Shaking flask by installing it on Universal shaking rack and angle rack■Application Container:500ml Shaking flask ■Standa ...
Stainless steel-made Top lid for M series | Stainless steel-made Top lid for M series
Stainless triangle lid special for MM-10/ML-10F.■: ■:
Monode kit | MD-3018
For Monod shake of L shape test tube. Remove spring net rack and replace it. Shaking angle is variable.■Applicable Container / Number:L shape test tube ( ...
Antifreeze | Show Brine Blue
Use when needed together with low temperature water bath unit or immersion cooler, use when setting below +7℃■Weight:20kg, 1 can ■:
Silicone oil | MA-50
Kinetic viscosity 50 mPa sec (cSt), 18 kg, for precise temperature control and use higher than +70℃.■Remarks:Kinetic viscosity 50 mPa sec (cSt), 18 kg ...
Silicone oil | MA-100
Kinetic viscosity 100 mPa sec (cSt), 18 kg, for use higher than +70℃.■Remarks:Kinetic viscosity 100 mPa sec (cSt), 18 k ...
Related Products
Shaking water bath | Cool bath shaker | ML-10F
Large size shaking water bath with quiet operation noise and easy to use. Low temperature available type can be addressed to Ames test.■Temperature range (*1):0℃ to +50℃ ■Temp. control accuracy (*2):±0.05℃ to 0.2℃