Aluminum block bath

Dry thermo unit DTU-1CN

Code No.: 0075930-000

The aluminum block Bath that heats and cools Microtubes, Centrifuge tubes, and Test tubes. The block enables vessels to be inserted deeply, which allows for the temp. control accuracy like a Constant temperature water bath. Compatible with the nitrogen gas spraying unit.

Aluminum block is option

Applications

Enzymatic reactions, Heat denaturation of DNA and RNA
Hydrolytic reaction of Sugar, Protein, Fatty acid, etc.
Concentration of Solvent with Nitrogen gas spraying (Optional)

Down Load(Useful Information)

General Catalog
Guide for aluminum blocks for different type of vessels

Features

Deep block for afford centrifuge tubes and test tubes
DTU-1CN holds one of specialized deep block which can hold 9 of 50ml disposable centrifuge tubes.
Meet to various containers with exchanging block
We have a several deep blocks (option) to meet with various containers.
Temperature accuracy as water bath
With sensor block system (PAT.P), it can control temperature accurately as water bath which is not achieved by conventional aluminum block bath.
C (chemical) type is for up to +200ºC
Can be used for condense evaporate and synthesis reaction which need high temperature.
DTU-1CN has simple OFF timer and buzzer timer.
DTU-1CN has simple ON timer, OFF timer and buzzer timer.
Condense with spraying nitrogen gas
With evaporation head (option), condensing sample by removing solvent is possible.

Specifications

ModelDTU-1CN
Temperature range+ 5℃ above Room temperature to + 200℃
Temp. control accuracyBelow ±0.1℃ (Set per 0.1℃)
Capacity1BN/1CN: Deep block × 1 pc
Other functionsAutomatic tuning, ON/OFF timer (1 min to 99 h 59 min), Setting time notification timer, Setting temp. reaching notification buzzer, Temp. memory × 3, temp. Output (DC 0 V to 1 V: 1CN/2CN) (*)
Temp. DisplayDigital (Preset/Current value)
Heater180 W
Safe devices/ protectionsFuse, Sensor open/short circuit alarm, High/Low temp absolute value alarm, Memory error, Automatic tuning error
Dimensions (W×D×H)/Weight1BN/1CN: 210 × 318 × 130 mm, Approx. 4 kg
Power supplyAC100V/2A (Need a step-down transformer)
Standard accessoriesBlock extraction hook handle × 1 pc (Blocks are sold separately)
(*)The current temperature can be outputted ("Alarm Out Cable AOC-2" is required for use).

Dimensions

Accessories

Deep block for disposable centrifuge tube | AL-1616F
For DTU-1BN/2BN/1CN/2CN (Centrifuge tube 15mL x 16)
■Applicable Container / Number:Centrifuge tube 15m ...
Deep block for disposable centrifuge tube | AL-2909F
For DTU-1BN/2BN/1CN/2CN (centrifuge tube 50mL x 9)
■Applicable Container / Number:centrifuge tube 50m ...
Deep block for disposable centrifuge tube | AL-5011F
For DTU-1BN/2BN/1CN/2CN (centrifuge tube 15mL x 8 + 50mL x 3)
■Applicable Container / Number:Centrifuge tube 15m ...
Deep block for Microtube | AL-0836
For DTU-1BN/2BN/1CN/2CN (Microtube 0.5mL x 36)
■Applicable Container / Number:Microtube 0.5mL x 3 ...
Deep block for Microtube | AL-1136
For DTU-1BN/2BN/1CN/2CN (Microtube 1.5mL x 36)
■Applicable Container / Number:Micro tube 1.5mL x ...
Deep block for Vials | AL-1336V
Deep block for DTU-1BN/CN and DTU-2BN/CN (36 pcs × 1.5/2mL Vials(φ12 x 32H mm))
■Capacity/Remarks:1.5/2 mL × 36 pcs (φ12 × 32H mm) ...
Deep block for Microtube | AL-1136B
For DTU-1BN/2BN/1CN/2CN (Microtube 2.0mL x 36)
■Applicable Container / Number:Micro tube 2.0ml x ...
Deep block for Microtube | AL-8136
For DTU-1BN/2BN/1CN/2CN (micro tube 0.5mL x 18 + 1.5mL x 18)
■Applicable Container / Number:Micro tube 0.5mL x ...
Deep block for Test tube | AL-1236
For DTU-1BN/2BN/1CN/2CN (Test tube φ12mm x 36)
■Applicable Container / Number:test tubeφ12mm x 36 ...
Deep block for Test tube | AL-1336
For DTU-1BN/2BN/1CN/2CN (Test tube φ13mm x 36)
■Applicable Container / Number:test tube φ13mm x 3 ...
Deep block for Test tube | AL-1525
For DTU-1BN/2BN/1CN/2CN (Test tube φ15mm x 25)
■Applicable Container / Number:test tube φ15mm x 2 ...
Deep block for Vials | AL-1525V
Deep block for DTU-1BN/1CN/2BN/2CN (25 pcs × 4mL Vials (φ15 x 45H mm))
■Capacity/Remarks:4 mL × 25 pcs (φ15 × 45H mm), Di ...
Deep block for Test tube | AL-1625
For DTU-1BN/2BN/1CN/2CN (Test tube φ16.5mm x 25)
■Applicable Container / Number:test tube φ16.5mm x ...
Deep block for Test tube | AL-1820
For DTU-1BN/2BN/1CN/2CN (Test tube φ18mm x 20)
■Applicable Container / Number:test tube φ18mm x 2 ...
Deep block for Test tube | AL-2116
For DTU-1BN/2BN/1CN/2CN (Test tube φ21mm x 16)
■Applicable Container / Number:test tube φ21mm x 1 ...
Deep block for Test tube | AL-2412
For DTU-1BN/2BN/1CN/2CN (Test tube 12 pcs (18 pcs (*))x 10 mL (φ22.5 x 46H mm))
■Applicable Container / Number:test tube φ24mm x 1 ...
Deep block for Vials | AL-2412V
Deep block for DTU-1BN/CN and DTU-2BN/CN (12 pcs × 10mL Vials)
■Capacity/Remarks:10 mL × 12 pcs (φ22.5 × 46H mm), ...
Deep block for Test tube | AL-2512
For DTU-1BN/2BN/1CN/2CN (Test tube φ25mm x 12)
■Applicable Container / Number:test tube φ25mm x 1 ...
Deep block for Test tube | AL-3009
For DTU-1BN/2BN/1CN/2CN (Test tube φ30mm x 9)
■Applicable Container / Number:test tube φ30mm x 9 ...
Deep block for Test tube | AL-3505
For DTU-1BN/2BN/1CN/2CN (Test tube φ35mm x 5)
■Applicable Container / Number:test tube φ35mm x 5 ...
Raising block | AL-0030V
Used for height adjustment in deep block for DTU-1BN / CN and DTU-2BN / CN.
■Applicable to:DTU-1BN/CN、DTU-2BN/CN ■Dimensions ( ...
Alarm out cable | AOC-2
For CL series
■Cable length:2m ■:

Related Products

Aluminum block bath | Dry thermo unit | DTU-Mini
The compact-sized aluminum block bath that heats and cools Microtubes and Centrifuge tubes. Fast temp. transition with thin block.
■Settable temperature range:0℃ to +105℃ ■Temperature range (*):+ 3℃ above Room temperature to + 95℃ above Room temperature
Aluminum block bath | Cool thermo unit | CTU-Mini
The compact-sized aluminum block bath that heats and cools Microtubes and Centrifuge tubes. Fast temp. transition with thin block. Cooled-type CTU with CFC-free.
■Settable temperature range:0℃ to +105℃ ■Temperature range (*):+ 30℃ below Room temperature to + 85℃ above Room temperatureTemp. control accuracy (*) ±0.1℃ to ±0.2℃ (Set per 0.1℃)
Aluminum block bath | Dry thermo unit | DTU-1BN
The aluminum block Bath that heats and cools Microtubes, Centrifuge tubes, and Test tubes. The block enables vessels to be inserted deeply, which allows for the temp. control accuracy like a Constant temperature water bath. Compatible with the nitrogen gas spraying unit.
■Temperature range:+ 5℃ above Room temperature to +110℃ ■Temp. control accuracy:Below ±0.1℃ (Set per 0.1℃)
Aluminum block bath | Dry thermo unit | DTU-2BN
The aluminum block Bath that heats and cools Microtubes, Centrifuge tubes, and Test tubes. The block enables vessels to be inserted deeply, which allows for the temp. control accuracy like a Constant temperature water bath. Compatible with the nitrogen gas spraying unit.
■Temperature range:+ 5℃ above Room temperature to +110℃ ■Temp. control accuracy:Below ±0.1℃ (Set per 0.1℃)
Aluminum block bath | Dry thermo unit | DTU-2CN
The aluminum block Bath that heats and cools Microtubes, Centrifuge tubes, and Test tubes. The block enables vessels to be inserted deeply, which allows for the temp. control accuracy like a Constant temperature water bath. Compatible with the nitrogen gas spraying unit.
■Temperature range:+ 5℃ above Room temperature to + 200℃ ■Temp. control accuracy:Below ±0.1℃ (Set per 0.1℃)
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-36
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Applicable type:DTU-1BN/2BN/1CN/2CN ■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-25
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Applicable type:DTU-1BN/2BN/1CN/2CN ■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-20
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Applicable type:DTU-1BN/2BN/1CN/2CN ■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-16
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm ■Number of nozzles:16
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-12
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Applicable type:DTU-1BN/2BN/1CN/2CN ■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-9
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Applicable type:DTU-1BN/2BN/1CN/2CN ■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm
Nitrogen gas spray unit for aluminum block bath | Evaporation head | EN1-5
For DTU-1BN/2BN/1CN/2CN. Unit for condense and dry by spraying nitrogen gas.
■Applicable type:DTU-1BN/2BN/1CN/2CN ■Dimension of spray nozzle:Outer diameter 2mm x inner diameter 1.5mm x effective length 88mm
Translate »