e-TAITEC.com

Product Info

Blotting device for hybridization

G Capillary Blotter D-set

Code No.: 0014676-000

The falling pad method rises transfer efficiency as gravity promotes the transfer of buffer in addition to water absorption by "Pad" and paper towel.


Applications

•Transfer in Southern blotting
•Transfer in northern blotting

Features

Works smaller amount of buffer than conventional one
The efficiency of falling pad method and the effect of water absorption pad reduce buffer amount.
The effective transfer for just 2 hours. Even DNA/RNA with large molecular amount.
Conventionally the membrane was placed on gel and the paper towel transferred the band to the membrane with the force of sucking up the buffer.
In other words it had defied gravity. This product realized to get synergy effect and prompt transfer by adding gravity to the capillary force of paper towel to buffer by placing the membrane under gel.
Transfers smoothly even DNA/RNA with large amount of molecular (See next page for the structure).
Resin water absorption pad can be used for many times
Resin water absorption pad adopted to reduce the amount of paper towel used. Enables use for many times by washing with water and naturally drying after use.
The structure of G Capillary blotter

As the gel placed on membrane and the water absorption pad placed under the gel, the buffer flows down by gravity and absorption and accordingly DNA and RNA in the gel are transferred to the membrane. Since DNA and RNA cannot pass through the membrane, they are trapped on membrane. The transfer continues as the buffer continues to flow downward by the absorbent pad.

Specifications

ModelG Capillary Blotter D-set
Max. Gel size120 x 120mm
ConfigurationPad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1515 (150 x 150 mm)
•As New pads might not have absorb water enough. Soak in the buffer for a while etc. before use.
Wash the pad with water and allow it to dry naturally after use it (The water absorption decrease if it put in the dryer etc.)

Related Products

Blotting device for hybridization | | G Capillary Blotter C-set
The falling pad method rises transfer efficiency as gravity promotes the transfer of buffer in addition to water absorption by "Pad" and paper towel.
■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | G Capillary Blotter Mini
For the transfer with conventional method. Water absorption pad reduces paper towel used."Pad" and paper towel.
■Max. Gel size:100 x 100mm ■Configuration:Pad bath, Buffer bath, Pad P-1212 (120 x 120 mm)
Blotting device for hybridization | | Pad type blotter A-set
For the transfer with conventional method. Water absorption pad reduces paper towel used.
■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use) (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | Pad type blotter B-set
For the transfer with conventional method. Water absorption pad reduces paper towel used.
■Max. Gel size:120 x 120mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use)(Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1515 (150 x 150 mm)
Translate »