e-TAITEC.com

Product Info

Blotting device for hybridization

G Capillary Blotter D-set

Code No.: 0014676-000

The falling pad method increases the transfer efficiency as gravity promotes the transfer of the buffer in addition to water absorption by "Pad" and paper towel.


Applications

Transfer in Southern blotting
Transfer in Northern blotting

Down Load(Useful Information)

General Catalog

Features

Works with a smaller amount of buffer than the conventional one
The efficiency of the falling pad method and the effect of the water absorption pad reduces the buffer amount.
The effective transfer in just 2 hours. Even DNA/RNA with a large molecular amount.
Conventionally, the membrane was placed on the gel, and the paper towel transferred the band to the membrane with the force of sucking up the buffer. In other words, it had defied gravity. This product was able to obtain the synergy effect and prompt transfer by adding gravity to the capillary force of the paper towel to buffer by placing the membrane under the gel. Smooth transfer of even DNA/RNA with a large molecular amount (See next page for the structure).
The Resin water absorption pad can be used for many times
The Resin water absorption pad is adopted to reduce the amount of paper towel used. It can be used for many times by washing with water and naturally drying after use.
The structure of the G Capillary blotter

As the gel is placed on the membrane and the water absorption pad is placed under the gel, the buffer flows down by gravity and absorption. Accordingly, the DNA and RNA in the gel are transferred to the membrane. Since the DNA and RNA cannot pass through the membrane, they are trapped on the membrane. The transfer continues as the buffer continues to flow downward by the absorbent pad.

Specifications

ModelG Capillary Blotter D-set
Max. Gel size120 x 120mm
ConfigurationPad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1515 (150 x 150 mm)
•If the new pads do not absorb enough water, soak them in the buffer for a while before use. Wash the pads with water and allow it to dry naturally after use (The water absorption decreases if it is put in the dryer, etc.)

Related Products

Blotting device for hybridization | | G Capillary Blotter C-set
The falling pad method increases the transfer efficiency as gravity promotes the transfer of the buffer in addition to water absorption by "Pad" and paper towel.
■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | G Capillary Blotter Mini
For transfers with the conventional method. The Water absorption pad reduces the amount of paper towel used.
■Max. Gel size:100 x 100mm ■Configuration:Pad bath, Buffer bath, Pad P-1212 (120 x 120 mm)
Blotting device for hybridization | | Pad type blotter A-set
For transfers with the conventional method. The Water absorption pad reduces the amount of paper towel used.
■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use) (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | Pad type blotter B-set
For transfers with the conventional method. The Water absorption pad reduces the amount of paper towel used.
■Max. Gel size:120 x 120mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use)(Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1515 (150 x 150 mm)
Translate »