For transfers with the conventional method. The Water absorption pad reduces the amount of paper towel used.
Applications
●Transfer in Southern blotting●Transfer in Northern blotting
Down Load(Useful Information)
General CatalogFeatures
The structure of the G Capillary blotter
As the gel is placed on the membrane and the water absorption pad is placed under the gel, the buffer flows down by gravity and absorption. Accordingly, the DNA and RNA in the gel are transferred to the membrane. Since the DNA and RNA cannot pass through the membrane, they are trapped on the membrane. The transfer continues as the buffer continues to flow downward by the absorbent pad.
The performance is even equivalent to that of the G Capillary blotter
Footprint is quite small. Corresponds to the gel with up to 100 × 100 mm. The transfer efficiency is equivalent to that of the G Capillary blotter C-set/D-set.Specifications
Model | G Capillary Blotter Mini |
---|---|
Max. Gel size | 100 x 100mm |
Configuration | Pad bath, Buffer bath, Pad P-1212 (120 x 120 mm) |
Related Products
Blotting device for hybridization | | G Capillary Blotter C-set
The falling pad method increases the transfer efficiency as gravity promotes the transfer of the buffer in addition to water absorption by "Pad" and paper towel.■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | G Capillary Blotter D-set
The falling pad method increases the transfer efficiency as gravity promotes the transfer of the buffer in addition to water absorption by "Pad" and paper towel.■Max. Gel size:120 x 120mm ■Configuration:Pad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1515 (150 x 150 mm)
Blotting device for hybridization | | Pad type blotter A-set
For transfers with the conventional method. The Water absorption pad reduces the amount of paper towel used.■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use) (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | Pad type blotter B-set
For transfers with the conventional method. The Water absorption pad reduces the amount of paper towel used.■Max. Gel size:120 x 120mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use)(Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1515 (150 x 150 mm)