e-TAITEC.com

Product Info

Blotting device for hybridization

G Capillary Blotter Mini

Code No.: 0031914-000

For the transfer with conventional method. Water absorption pad reduces paper towel used."Pad" and paper towel.


Applications

•Transfer in Southern blotting
•Transfer in northern blotting

Features

The structure of G Capillary blotter

As the gel placed on membrane and the water absorption pad placed under the gel, the buffer flows down by gravity and absorption and accordingly DNA and RNA in the gel are transferred to the membrane. Since DNA and RNA cannot pass through the membrane, they are trapped on membrane. The transfer continues as the buffer continues to flow downward by the absorbent pad.
The performance even equivalent to that of G Capillary blotter
Footprint quite small. Corresponds to the gel with up to 100 x 100mm.
The transfer efficiency equivalent to that of G Capillary blotter C-set/D-set.

Specifications

ModelG Capillary Blotter Mini
Max. Gel size100 x 100mm
ConfigurationPad bath, Buffer bath, Pad P-1212 (120 x 120 mm)
•As New pads might not have absorb water enough. Soak in the buffer for a while etc. before use.
Wash the pad with water and allow it to dry naturally after use it (The water absorption decrease if it put in the dryer etc.)

Related Products

Blotting device for hybridization | | G Capillary Blotter C-set
The falling pad method rises transfer efficiency as gravity promotes the transfer of buffer in addition to water absorption by "Pad" and paper towel.
■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | G Capillary Blotter D-set
The falling pad method rises transfer efficiency as gravity promotes the transfer of buffer in addition to water absorption by "Pad" and paper towel.
■Max. Gel size:120 x 120mm ■Configuration:Pad bath PB-2426 (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Buffer bath (upper part) BF-2426
Pad P-1515 (150 x 150 mm)
Blotting device for hybridization | | Pad type blotter A-set
For the transfer with conventional method. Water absorption pad reduces paper towel used.
■Max. Gel size:150 x 220mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use) (Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1824 (180 x 240 mm)
Blotting device for hybridization | | Pad type blotter B-set
For the transfer with conventional method. Water absorption pad reduces paper towel used.
■Max. Gel size:120 x 120mm ■Configuration:Pad bath PB-2426 (Buffer bath combined use)(Base part 350 x 220 mm, Bath inner 290 x 200 x 40Hmm)
Pad P-1515 (150 x 150 mm)
Translate »