e-TAITEC.com

Product Info

Hot water circulator

HC-03

Code No.:

Circulation of hot water up to +80℃ with high accuracy ±0.5℃. Various customized options such as heater output and pump capacity are available upon request.


Applications

•Hot water circulation for molding machines, Semiconductor manufacturing equipment, air conditioners, etc.
•Temperature control of chocolate, etc. in fermentation tanks and production lines
•A source of heat load for equipment development and testing

Down Load(Useful Information)

General Catalog

Features

Hot water circulator with high accuracy. Various customized such as heater output and number of pumps, etc.
Heating temperature control with high accuracy ±0.5℃ in temperature range +40℃ to +80℃. Various customized options such as heater output, number of pumps, piping material, etc. based on the following models. Please feel free to contact us.
Examples of Customization
•The primary cooling water is required when cooling function added.

The hot water circulators in the HC series are not equipped with compressors and use heaters to heat the water.
When operating at temperatures below 60℃ or when the temperature of the return water rises, a heat-absorbing mechanism with primary cooling water circulation must be added. The photo on the left shows an example of the specification with an additional cooling water circulation port.
*The primary cooling water is required when the cooling function added. The cooling capacity depends on the cooling water conditions (Water temperature and Flow rate).
To maintain circulation at high temperatures, connect with hoses, etc. with specifications that are heat resistant or insulated.
Examples of Customization
•Addition of Pump (up to 4 units)

Example of Pump 2 units mounted


The standard is One unit. Up to 4 units as an option.
*Theexternal dimensions may be changed depending on the number of pumps. Please ask us for details.

Specifications

ModelHC-03
Temperature range+40℃ to+80℃(*1)
Control accuracyPID controller, ±0.5℃ (*2)
Heater output3.0kW
Pump capacity(50/60Hz)Max. discharge pressure: 0.52MPa
Flow rate: 22/31 L/min (*3)
Motor output: 0.4kW
Water bath capacity (at 80% water level)28L
Safety device/functionShort/Over current breaker, Phase-reversal relay, Warning and Cut off for low water, Circulating water high temperature, Pump overcurrent, Overheating protection
Connecting pipe diameter (Circulating fluid in/out)Rc3/4
Dimensions386×512×865H mm
Weightapprox. 90kg
Power Supply (three phase AC200V, 50/60Hz)15A
Operation current(50/60Hz)12A
(*1)The lower limit may change depending on operating conditions. Cannot be used for applications on circulating water returns for temperature increases.
(*2)Cooling water is required up to approx. +60℃.
(*3)Capacity when using tap water. The value when the discharge pressure at 0.3 MPa.
•The sensitivity current in ELCB should be set larger than 30 mA.
•The primary cooling water is required when the cooling function is added. The cooling capacity depends on the cooling water conditions (Water temperature and Flow rate).

Related Products

Hot water circulator | | HC-06
Circulation of hot water up to +80℃ with high accuracy ±0.5℃. Various customized options such as heater output and pump capacity are available upon request.
■Temperature range:+40℃ to+80℃(*1) ■Control accuracy:PID controller, ±0.5℃ (*2)
Hot water circulator | | HC-09
Circulation of hot water up to +80℃ with high accuracy ±0.5℃. Various customized options such as heater output and pump capacity are available upon request.
■Temperature range:+40℃ to+80℃(*1) ■Control accuracy:PID controller, ±0.5℃ (*2)
Hot water circulator | | HC-12
Circulation of hot water up to +80℃ with high accuracy ±0.5℃. Various customized options such as heater output and pump capacity are available upon request.
■Temperature range:+40℃ to+80℃(*1) ■Control accuracy:PID controller, ±0.5℃ (*2)
Hot water circulator | | HC-15
Circulation of hot water up to +80℃ with high accuracy ±0.5℃. Various customized options such as heater output and pump capacity are available upon request.
■Temperature range:+40℃ to+80℃(*1) ■Control accuracy:PID controller, ±0.5℃ (*2)
Hot water circulator | | HC-24
Circulation of hot water up to +80℃ with high accuracy ±0.5℃. Various customized options such as heater output and pump capacity are available upon request.
■Temperature range:+40℃ to+80℃(*1) ■Control accuracy:PID controller, ±0.5℃ (*2)
Translate »