e-TAITEC.com

Product Info

Non-contact turbidimeter for Shaking culture

OD-Monitor OD-Monitor C&T

Code No.:

The turbidity can be measured at OD600 noncontact while shaking. For test tubes.


Applications

Examination and screening of beneficial bacteria.
Labor-saving acquisition of growth curve
Background reduction by sampling

Down Load(Useful Information)

General Catalog

Features

Recorded data
OD BOX can record up to 360 points.
(Point=Total measured time ÷ Measurement interval)
The acquired data can be stored in a USB and output to PC In TXT format of CSV.
The turbidity is 0 at the start of measurement and display measured values.
It measures turbidity based on the size of E. coli, you need to correct the turbidity of targeted bacteria by spectrophotometer.
Operated with Bioshaker in combination.
Fix ODSensor with the clamp on the platform inside Bioshaker BR-series (w/o BR-180LF-70RT) and put the vessel on it. It can be also used in Shaker NR series.

Specifications

ModelOD-Monitor C&T
Measurement method/rangeLight transmission, 0.00 to 2.55 (OD600)
Vessel and Fluid volumeVessel: Glass Test tube Size: φ16.5/18.0 mL Fluid volume: 5 mL or 10 mL
Shaking methodReciprocal shaking
Shaking conditions100 to 250 r/min (Shaking width 25/50 mm) Angle of Test tube 90/45/30°
Measurement intervals/channel1/5/10/30/60/120/240 min, 1 to 8 (A&S)/1 to 8 (C&T) (*)
Ambient temp. range+15℃ to +50℃
Power supplyAC100V-240V/1A (universal power supply)
Standard accessories for ODBoxFlat cable (2 m) ×1 pc, *For A&S, Power cable ×1 pc
Standard accessories for ODSensorMagnet adapter (2 types) ×1 pc, Flat cable (2 m)× 4 pcs
(*)A&S equipped with 1 channel per 1 set of ODSensor. Some number of ODSensor should be required depending on the number of samples. C&T equipped with 8 channels per 1 set of ODSensor can be connected with only 1 set of ODBox. ODSensor with maximum number of channels cannot be put in Bioshaker depending on its size. Ask us for details.

Details of Set Products

ModelODBox-C
Display of (OD) valueDisplay of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria
Measurement Range0.00 to 2.55 (accuracy guarantee range 0.20 to 2.00)
Correction for biological species other than E. coli bacteria and gap from spectrophotometerEnter correction factors (0.01 - 2.55、initial value is 1.00)
Interval1/5/10/30/60/120/240min
Angle of test tubes90/45/30°
Maximum Measurement TimeInternal memory : 360 points (*1)
USB memory : Up to USB memory
Maximum Connectable ODSensor-T1 (8ch), Measurement under all same conditions
Interface for external storage mediumPort for USB2.0 flash memory (*2)
Other FunctionsAlarm by buzzer when over target OD
Dimensions153×220×127Hmm
(*1)Point = Total measurement time / Interval. The 360th point figure is to updated when it exceed 360 points.
(*2)Some memory cannot be used with this unit even if it can be used with a personal computer.
ModelODSensor-T
Measurement MethodLight transmission, infrared light
Measurement Wavelength950nm
ConnectionOne set (use attached 2m flat cable )
Power SupplySupplied from ODBox-C (option)
Standard AccessoryFlat cable (2m) x 4, 1 x Magnet adapter (2 types)

Accessories

Universal shaking platform | MT-2925
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:290 x 250 x 23Hmm ■Weight:Approx. 0.9k ...
Universal shaking platform | MT-4030
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:400 x 300 x 23Hmm ■Weight:Approx.1.4Kg
Universal shaking platform | MT-7050
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:700 x 500 x 22Hmm ■Weight:Approx. 6Kg

Related Products

Non-contact turbidimeter for Shaking culture | OD-Monitor control unit | ODBox-C
It is a control unit of OD-Monitor C & T.
■Display of (OD) value:Display of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria ■Measurement Range:0.00 to 2.55 (accuracy guarantee range 0.20 to 2.00)
Non-contact turbidimeter for Shaking culture | OD-Monitor measurement unit | ODSensor-T
It is a measurement unit of OD-Monitor C & T.
■Measurement Method:Light transmission, infrared light ■Measurement Wavelength:950nm
Small size constant temperature incubator shaker | Bioshaker | BR-22FP
Widely used for Cultivation of microbes, etc. that require temp. control. Its compact sized can be placed under and on the Lab bench.
■Temperature Range:+15ºC to +60ºC (Low - middle temperature)(*1) ■Shaking motion:Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-23FP
Widely used for Cultivation of microbes, etc. that require temp. control. Its compact sized can be placed under and on the Lab bench.
■Temperature Range:+15ºC to +60ºC (Low - middle temperature)(*1) ■Shaking motion:Reciprocal/Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-22UM
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 70℃ ■Shaking motion:Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-23UM
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 70℃ ■Shaking motion:Reciprocal/Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-22FH
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 100℃ ■Shaking motion:Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-23FH
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 100℃ ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-40LF
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility
■Temperature range:+4ºC to +70ºC (For low to medium temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-42FL
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+4ºC to +70ºC (For low to medium temperatures) ■Shaking motion:Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-43FL
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+4ºC to +70ºC (For low to medium temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-42FM
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+5℃ above RT to +70℃ (For medium temperatures) ■Shaking motion:Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-43FM
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+5℃ above RT to +70℃ (For medium temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-43FH
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+5℃ above RT to +100℃(For medium to high temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-53FP
Peltier cooling with CFC-free. Temperature range ensures 15℃ to 55℃. Cut power consumption by 80% with the conventional one.
■Temperature range (*1):+15℃ to +55℃ (room temperature -10℃ to room temperature +30℃) ■Shaking motion:Switchable Reciprocal/Orbital shaking
Large size constant temperature incubator shaker | Bioshaker | GBR-200
Enables to use widely for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. High-end model that features for stackable, wide range of temp. range, and speed. Cut power consumption by 75% with the conventional one!
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Temperature range:+4℃ to +80℃
Large size constant temperature incubator shaker | Bioshaker | GBR-300
Enables to use widely for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. High-end model that features for stackable, wide range of temp. range, and speed. Cut power consumption by 75% with the conventional one!
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Temperature range:+4℃ to +80℃
Large size constant temperature incubator shaker | Bioshaker | BR-180LF
Split doors enable large vessels to be taken in and out easily. Can be modified to Forced ventilation system of carbon dioxide.
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Temperature range:+4℃ to +70℃
Large size constant temperature incubator shaker | Bioshaker | BR-300LF
TAITEC's largest capacity Bioshaker, remodeled with improved usability.
■Temperature range:+4℃ to +70℃ ■Temp. control accuracy (*1):±0.3℃ to ±1.0℃
Translate »