Product Info
Bench-top shaking water bath
Shaking water bath Personal-11 EXN Set
Code No.: 0072971-000
Versatile Bench-top Water bath that is equipped with Reciprocal shaking. Unique Monode shaking platform for shaking L-shaped test tubes is available as an option.
Applications
●Incubation of microorganisms such as E. Coli●Various incubation such as enzyme reaction at high temperature
●Hybridization
Down Load(Useful Information)
General CatalogFeatures
Temperature setting using Up-Down key, EXN-B has ON-OFF timer
Up-Down key can set temperature in unit of 0.1ºC. Setting temperature and actual temperature are digital display. EXN-B can be operated by ON-OFF timer and OFF-ON timer. EXN-B also has buzzer timer.EXN-B can memorize three temperature settings.
EXN-B can memorize three temperature settings. By combination with ON/OFF/buzzer timer and temp. memory, EXN can perform three step simple program.Easy takeout of thermoregulation part, inner package of water bath and shaking rack
Thermo minder (thermoregulation part), shaking rack and water bath can be takeout easily. Machine body (except float switch), wetted surface and shaking rack are all made of stainless steel. It is enduring and always kept clean.Adjustable shaking speed and amplitude
Amplitude can be adjusted machinery.Specifications
Model | Personal-11 EXN Set |
---|---|
Temperature range (*2)(Thermominder) | 5℃ above RT to +70℃ (Preset/Current temp. displayed simultaneously in the SDN/EXN switch. Switchable Preset/Current temp display in SM.) |
Temp. control accuracy (*3)(Thermominder) | ±0.02℃ to 0.08℃ |
Temperature memory(Thermominder) | 3 |
Temperature memory(Thermominder) | 1 |
Timer (*4)(Thermominder) | Buzzer notification for Preset time,Operation OFF/Operation ON |
Other functions(Thermominder) | Buzzer notification when preset temp. is reached, |
Simple Program (3 Steps), Safety device output,Temp. input/output, Automatic tuning | |
Heater(Thermominder) | 800 W |
Safe devices/protections(Thermominder) | Circuit protector, Fuse, Dry-heating protection with float, Heater protection cover (SM-05N), Sensor error, Short circuit, High/Low temp. Sample protection,Water level alarm, Non-volatile memory error, Automatic tuning error, Alarm setting error, Switchable Automatic/Manual recovery when power failure |
Power supply(Thermominder) | AC 100 V/8.5 A |
Shaking method(Personal) | Reciprocal shaking, Shaking speed: 20 to 160 r/min (displayed digitally), Shaking width: 10 to 40 mm (Stepless variable, Default 30 mm) |
Platform dimensions(Personal) | 220 × 310 mm |
Other functions(Personal) | Elapsed time indicator (0.1 to 999.9 h, with Automatic reset) × 1 , Service outlet for Thermominder ×1 |
Bath inside dim.(W×D×H)/volume(Personal) | 235 × 430 × 140 mm, Approx. 11 L (80% Water level) (*6) |
Power supply(Personal) | AC100V/0.5A /Max.9A with EXN(Need a step-down transformer) |
Standard accessories(Personal) | Spring net Shaking Platform × 1 pc, Clamp Spacer × 1 pc |
Dimensions (W×D×H)/weight | 300 × 495 × 336 mm, Approx. 19 kg |
(*1)Can be combined with SJ-07N and SX-10N. | |
(*2)Max. temp. may not be reached when the optional Hood is not used or depending on the usage conditions. | |
(*3)The value under the conditions of RT (25℃), AC 100V/50 Hz, 80% Water level, Preset temp. 37℃, and No heat load. Only for EXN Measured value. | |
(*4)Each setting range is 1 min to 99 h 59 min. | |
(*5)This also serves as a packing box whereas it is not used together with | |
the Personal-11 Set. | |
(*6)The proper volume is 7 L to 9 L when shaking with the capacity (max. number) such as Centrifuge tubes and max. 500 mL of Erelnmeyer flasks at 120 to 160 r/min. |
Details of Set Products
Model | EXN |
---|---|
Temperature Range | RT+5ºC - +70 ºC |
Temperature setting | -20℃ - +100℃ (*1) |
Temp. Control Accuracy | ±0.02ºC - 0.08 ºC |
Minimum temperature setting unit | 0.1ºC (setting and display) |
Flow | Jet blast Flow control : 4 step (digital display) |
Temperature Display | Digital display Setting temperature (top panel) and inside chamber temperature (side panel) |
Timer | ON-OFF: 1min - 99h59min Buzzer : 1min - 99h59min OFF-ON: 1min - 99h59min |
Memory | three memory |
Simple_Programming Function | three steps |
Heater | 800W |
Weight | Approx. 3kg (when using thermal insulation tray B: Approx. 6kg) |
Safety device / function | Circuit protector (15A), fuse (2A), float type prohibition of boiling while empty Warning buzzer, misalignment high and low temperature error , lowing water, sensor error, auto tuning error, non-volatile storage error |
Dimensions | 280 x 109 x 215Hmm (when using thermal insulation tray B: 280 x 475 x 240Hmm) |
Power Supply | AC100V/8.5A (Need a step-down transformer) |
(*1) Cooling machine such as "Cool pipe" is required for set below environmental temperature. Antifreezing solution is required for set below +7℃. |
Accessories
Heat-resistant Plastic Hood | PF-P
Cover to prevent evaporation of water and make the machine into moist chamber.■: ■:
Monode kit | MD-1218
Monod shaking rack of L-shape test tube. Replace with spring net shaking rack.■Applicable Container / Number:L-shape test tube ( ...
Monitor connector | CA-671
Sub connector for EXN-B■: ■:
External sensor | CA-760
External sensor for Thermominder EXN-B■: ■:
Related Products
Unit water bath | Thermominder | EXN-B
Addressed to low water of 45mm to fit to micro tube and small test tube. Optimum for examination.■Temperature Range:RT+5ºC - +70 ºC ■Temperature setting:-20℃ - +100℃ (*1)
Bench-top shaking water bath | shaking water bath | Personal-11 SDN Set
Standard shaking water bath for personal use. Set of Personal-11 and Thermominder SDN.■Product contents:Thermoregulation part:SDNShaker part:Personal-11 ■Dimensions:300 x 495 x 336Hmm
Bench-top shaking water bath | Shaking water bath | Personal Monode SDN Set
Versatile Bench-top Water bath that is equipped with Reciprocal shaking. Unique Monode shaking platform for shaking L-shaped test tubes is available as an option.■Temperature range (*2)(Thermominder):5℃ above RT to +70℃ (Preset/Current temp. displayed simultaneously in the SDN/EXN switch. Switchable Preset/Current temp display in SM.) ■Temp. control accuracy (*3)(Thermominder):±0.1℃ to 0.3℃
Bench-top shaking water bath | Shaking water bath | Personal-11 SM Set
Versatile Bench-top Water bath that is equipped with Reciprocal shaking. Unique Monode shaking platform for shaking L-shaped test tubes is available as an option.■Temperature range (*2)(Thermominder):5℃ above RT to +70℃ (Preset/Current temp. displayed simultaneously in the SDN/EXN switch. Switchable Preset/Current temp display in SM.) ■Temp. control accuracy (*3)(Thermominder):±0.1℃
Bench-top shaking water bath | Shaking water bath | Personal-11 SJ Set
Set of Personal-11 and Thermominder SJ-07N.■Product contents:Thermoregulation part:SJ-07NShakier part:Personal-11 ■Dimensions:300 x 485 x 440Hmm
Bench-top shaking water bath | Shaking water bath | Personal-11 SX Set
Set of personal-11 and Thermominder SX-10N.■Product contents:Thermoregulation part:SX-10NShakier part:Personal-11 ■Dimensions:300 x 485 x 440Hmm
Bench-top shaking water bath | Shaking water bath | Personal Lt-10F SX Set
Versatile Bench-top Water bath is equipped with Reciprocal shaking. 2 models for Low temp. and for High temp. For Cultivation of Particular Microbe and Preparation of Analysis samples.■Temperature range (*1)(Thermominder):-10℃ to +50℃ ■Settable temp. range (*2)(Thermominder):-20℃ to +105℃ (5℃ to 105℃ in SX-10N used singly)
Bench-top shaking water bath | Shaking water bath | Personal H-10 SH Set
Versatile Bench-top Water bath is equipped with Reciprocal shaking. 2 models for Low temp. and for High temp. For Cultivation of Particular Microbe and Preparation of Analysis samples.■Temperature range (*1)(Thermominder):+5℃ above RT to +180℃ ■Settable temp. range (*2)(Thermominder):-20℃ to +180℃