e-TAITEC.com

Product Info

Non-contact turbidimeter for Shaking culture

OD-Monitor OD-Monitor A&S

Code No.:

The industry's first Non-contact turbidimeter that can measure the turbidity of sample at OD600 while shaking. Adopted among the hundreds of R&D institutions. Operated with Bioshaker (Incubator shaker) in combination.


Applications

Labor-saving acquisition of growth curve
Background reduction by sampling

Down Load(Useful Information)

General Catalog

Features

Recorded data
OD BOX can record up to 360 points.
(Point=Total measured time ÷ Measurement interval)
The acquired data can be stored in a USB and output to PC In TXT format of CSV.
The turbidity is 0 at the start of measurement and display measured values.
It measures turbidity based on the size of E. coli, you need to correct the turbidity of targeted bacteria by spectrophotometer.
Used with the shaker (rotating type)
It is used with incubator shaker BR series or double shaker NR series.
(The shaker of the other companies cannot be used) .
Install the measurement unit to rack only.

Image of conbination with BR-43FL

Image of conbination with BR-180LF

Image of conbination with NR-3
Eight channels in maximum, The measurement value is converted to OD600 of the spectrophotometer.
It measure 8ch in maximum at the same time.
The measurement value is converted into 600 nm of the spectrophotometer (our BPM-10Bio).

Specifications

ModelOD-Monitor A&S
Measurement method/rangeLight transmission, 0.00 to 2.55 (OD600)
Vessel and Fluid volumeVessel: Glass Erlenmeyer flask Size: 100/200/300/500 mL Fluid volume: 20/40/60/100 mL
Shaking methodOrbital shaking
Shaking conditions80 to 400 r/min (Shaking width 25 mm)/80 to 200 r/min(Shaking width 30/40 mm) 80 to 250 r/min (Shaking width 50 mm)
Ambient temp. range+15℃ to +50℃
Other functionsAlarm for specific value at OD, Transformation to Spectrophotometer in measurement value, USB flash drive (CSV file), Operation for pump unit (B&L) when above specified OD value
Power supplyAC100V-240V/1A (universal power supply)
Standard accessories for ODBoxFlat cable (2 m) ×1 pc, *For A&S, Power cable ×1 pc
Standard accessories for ODSensorVibration absorbing pad of Flask (large and small) ×1 pc, Flat cable (0.5 m) ×1 pc
(*)A&S equipped with 1 channel per 1 set of ODSensor. Some number of ODSensor should be required depending on the number of samples. C&T equipped with 8 channels per 1 set of ODSensor can be connected with only 1 set of ODBox. ODSensor with maximum number of channels cannot be put in Bioshaker depending on its size. Ask us for details.

Details of Set Products

ModelODBox-A
Display of (OD) valueDisplay of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria
Measurement Range0.1 - 2.0(accuracy guarantee range 0.5 - 1.5)
Correction for biological species other than E. coli bacteria and gap from spectrophotometerEnter correction factors (0.01 - 2.55、initial value is 1.00)
Correction allowance / Correction rangeWithin 15% (OD = 0.5 - 1.5)
Interval1/5/10/30/60/120/240min
Maximum Measurement TimeInternal memory : 360 points (*1)
USB memory : Up to USB memory
Maximum Connectable ODSensor-S8sets(2ch x 4), Measurement under all same conditions
Interface for print outputRS-232C (*2)
Interface for external storage mediumPort for USB2.0 flash memory (*3)
Other FunctionsAlarm function (alarm by buzzer at reached target OD) (*4)
Dimensions153 x 220 x 127Hmm
Standard AccessoryFlat cable (2m) x 1
(*1)Point = Total measurement time / Interval. The 360th point figure is to updated when it exceed 360 points.
(*2)The recommended cable is KRS-433XF07K made by SANWA SUPPLY and the recommended rollpaper printer is BL2-58NBJC made by SANEI DENKI corporation.
(*3)Some memory cannot be used with this unit even if it can be used with a personal computer.
(*4)If it reaches the target value, a buzzer may not immediately ring depending on setting of interval.
●ODSensor-S is sold separately.
ModelODSensor-S
Measurement MethodInfrared rays penetration light method (horizontal projection)
Measurement Wavelength950nm
ConnectionOne set (use attached 0.5m flat cable )
Power SupplySupplied from ODBox-A (option)
Standard AccessoryFlask pad large, small x each 1,Screw for installation (M4x15mm) x 6, Cable clip large x 2 + small x 4, Flat cable (0.5m) x 1
(*)Large is for 300ml and small is for 100/200ml. The pad for 500ml is attached to clamp CF-0500.
●ODBox-A, Clamp is sold separately.

Accessories

Clamp | CF-0100
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:100ml Erlenmeyer flask ■:
Clamp | CF-0200
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:200ml Erlenmeyer flask ■:
Clamp | CF-0300
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:300ml Erlenmeyer flask ■Sta ...
Clamp | CF-0500
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:500ml Erlenmeyer flask ■Sta ...
Universal shaking platform | MT-2925
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:290 x 250 x 23Hmm ■Weight:Approx. 0.9k ...
Universal shaking platform | MT-4030
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:400 x 300 x 23Hmm ■Weight:Approx.1.4Kg
Flat cable(2m) | OD-CAV0200
Connecting cable between ODBox and ODSensor
■: ■:
Color cap & tag | OD-CAP0408
Cable tag for identifying each sensor
■: ■:

Related Products

Non-contact turbidimeter for Shaking culture | OD-Monitor control unit | ODBox-A
It is a control unit of OD-Monitor A & S.
■Display of (OD) value:Display of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria ■Measurement Range:0.1 - 2.0(accuracy guarantee range 0.5 - 1.5)
Non-contact turbidimeter for Shaking culture | OD-Monitor measurement unit | ODSensor-S
It is a measurement unit of OD-Monitor A & S.
■Measurement Method:Infrared rays penetration light method (horizontal projection) ■Measurement Wavelength:950nm
Non-contact turbidimeter for Shaking culture | OD-Monitor | OD-Monitor B&L
OD-Monitor B&L can be used with 1L-3L flasks. Operated with Bioshaker (Incubator shaker) in combination.
■Measurement method/range:Light transmission/Reflected light, 0.00 to 9.99 (OD600) ■Vessel and Fluid volume:Vessel: Glass Erlenmeyer flask Size: 1/2/3 L Fluid volume: 350/700/1000 mL
Non-contact turbidimeter for Shaking culture | OD-Monitor | OD-Monitor C&T
The turbidity can be measured at OD600 noncontact while shaking. For test tubes.
■Measurement method/range:Light transmission, 0.00 to 2.55 (OD600) ■Vessel and Fluid volume:Vessel: Glass Test tube Size: φ16.5/18.0 mL Fluid volume: 5 mL or 10 mL
Small size constant temperature incubator shaker | Bioshaker | BR-22FP
Widely used for Cultivation of microbes, etc. that require temp. control. Its compact sized can be placed under and on the Lab bench.
■Temperature Range:+15ºC to +60ºC (Low - middle temperature)(*1) ■Shaking motion:Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-23FP
Widely used for Cultivation of microbes, etc. that require temp. control. Its compact sized can be placed under and on the Lab bench.
■Temperature Range:+15ºC to +60ºC (Low - middle temperature)(*1) ■Shaking motion:Reciprocal/Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-22UM
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 70℃ ■Shaking motion:Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-23UM
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 70℃ ■Shaking motion:Reciprocal/Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-22FH
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 100℃ ■Shaking motion:Orbital
Small size constant temperature incubator shaker | Bioshaker | BR-23FH
Small type of combined usability and space-saving
■Temperature Range:5℃ above RT to 100℃ ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-40LF
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility
■Temperature range:+4ºC to +70ºC (For low to medium temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-42FL
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+4ºC to +70ºC (For low to medium temperatures) ■Shaking motion:Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-43FL
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+4ºC to +70ºC (For low to medium temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-42FM
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+5℃ above RT to +70℃ (For medium temperatures) ■Shaking motion:Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-43FM
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+5℃ above RT to +70℃ (For medium temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-43FH
Widely used for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. Sufficient capacity, Space saving, and High versatility.
■Temperature range:+5℃ above RT to +100℃(For medium to high temperatures) ■Shaking motion:Reciprocal/Orbital
Medium size constant temperature incubator shaker | Bioshaker | BR-53FP
Peltier cooling with CFC-free. Temperature range ensures 15℃ to 55℃. Cut power consumption by 80% with the conventional one.
■Temperature range (*1):+15℃ to +55℃ (room temperature -10℃ to room temperature +30℃) ■Shaking motion:Switchable Reciprocal/Orbital shaking
Large size constant temperature incubator shaker | Bioshaker | GBR-200
Enables to use widely for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. High-end model that features for stackable, wide range of temp. range, and speed. Cut power consumption by 75% with the conventional one!
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Temperature range:+4℃ to +80℃
Large size constant temperature incubator shaker | Bioshaker | GBR-300
Enables to use widely for Cultivation of microbes such as Yeasts, E. coli, etc. that require temp. control and shaking. High-end model that features for stackable, wide range of temp. range, and speed. Cut power consumption by 75% with the conventional one!
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Temperature range:+4℃ to +80℃
Large size constant temperature incubator shaker | Bioshaker | BR-180LF
Split doors enable large vessels to be taken in and out easily. Can be modified to Forced ventilation system of carbon dioxide.
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Temperature range:+4℃ to +70℃
Large size constant temperature incubator shaker | Bioshaker | BR-300LF
TAITEC's largest capacity Bioshaker, remodeled with improved usability.
■Temperature range:+4℃ to +70℃ ■Temp. control accuracy (*1):±0.3℃ to ±1.0℃
Small size shaker | Rotary shaker | NR-2
Long selling small shaker easy operation inside constant temperature chamber. NR-2 suitable for mainly Erlenmeyer flask.
■Shaking motion:Orbital shaking ■Shaking Speed:20 to 200 r/min
Small size shaker | Double shaker | NR-3
Long selling small shaker easy operation inside constant temperature chamber. NR-3 can perfume both reciprocal and rotary shake.
■Shaking motion:Switchable Reciprocal/Orbital shaking ■Shaking Speed:20 to 200 r/min
Middle size shaker | Rotary shaker | NR-20
The versatile shaker with simple operation. Reciprocal, Orbital, Switchable Reciproca/Orbitall shaking, and Swing in figure 8. Options are compatible with those of Bioshaker® (Middle size).
■Shaking motion:Orbital ■Shaking Speed:20 to 200 r/min (*)
Middle size shaker | Double shaker | NR-30
The versatile shaker with simple operation. Reciprocal, Orbital, Switchable Reciproca/Orbitall shaking, and Swing in figure 8. Options are compatible with those of Bioshaker® (Middle size).
■Shaking motion:Switchable Reciprocal/Orbital ■Shaking Speed:20 to 200 r/min (*)
Middle size shaker | Triple shaker | NR-80
The versatile shaker with simple operation. Reciprocal, Orbital, Switchable Reciproca/Orbitall shaking, and Swing in figure 8. Options are compatible with those of Bioshaker® (Middle size).
■Shaking motion:Reciprocal/Orbital/Figue 8 ■Shaking Speed:20 to 200 r/min (*)
Translate »