e-TAITEC.com

Product Info

Non-contact turbidimeter for Shaking culture

OD-Monitor OD-Monitor B&L

Code No.:

New line up for OD-Monitor measurable OD while cultured as usual! It is for large Erlenmeyer flasks measurable high concentration. Automatic supply of IPTG at set value is possible with a pump unit.


Applications

Cell density observation of bacterial in culturing
Cell density observation of pathogenic bacteria
Cell observation of bacillus in culturing under anaerobic conditions which gas concentration is important
Cell density observation of bacteria with slow multiplication rate
Cell density observation of floating mammals cell (scheduled)
Variation of inoculum culture
Effective protein’s mass production byE.Coli etc

Features

Saving of the turbidity measurement in culture with reasonable price
It automatically and untouched measure turbidity of rotating culture, such as coliform bacillus, in 100/200/300/500ml glass Erlenmeyer flask (volume is 1/5 amount ±10%, no Sakaguchi and no baffle).
Use with  our Bio Shaker (middle size or larger recommended)
It is used with incubator shaker BR series. You just only attach the sensor unit to the shaking rack.
Four channels in maximum, The measurement value is converted to OD600 of the spectrophotometer.
It measure 4ch in maximum at the same time.
The measurement value is converted into 600 nm of the spectrophotometer (our BPM-10Bio).
It is possible to correct gap from the spectrophotometer.
It alarms you when reached set OD by buzzer.
The control unit displays the present value and target value.
When exceeding target value, it is possible to alarm by buzzer.
Data is saved to USB memory.
Data is saved by text format to the flash memory of USB2.0 (some is not used).
The edit with spreadsheet is possible.

Specifications

ModelOD-Monitor B&L
Component UnitControl unit :ODBox-B
Measurement unit :ODSensor-L
Temperature range of measurement+15ºC - +50ºC(Be careful of setting temperature of bio shaker.)
Applied Erlenmeyer flask and volume100/200/300/500ml flask made transparent glasses (no colored and no baffle), 1/5 volume±10% (*)
Shaking MethodRotating (It should shake on either of following conditions.)
Shaking speed and shaking amplitude100/120/150/160/180/200/240/250 r/min or 25/50mm (*)
(*) Set with ODBox-B at the beginning of measurement . OD-Monitor can be used only with TAITEC's incubator shaker BR series (current models ). Be sure to check shaking amplitude when you measure and ground both ODBox-B and a shaker for reducing electric noise.

Details of Set Products

ModelODBox-B
Display of (OD) valueDisplay of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria
Measurement Range0.1 - 9.9(accuracy guarantee range 0.3 - 7.0)
Correction for biological species other than E. coli bacteria and gap from spectrophotometerEnter correction factors (0.01 - 2.55、initial value is 1.00)
Interval1/5/10/30/60/120/240min
Maximum Measurement TimeInternal memory : 360 points (*1)
USB memory : Up to USB memory
Maximum Connectable ODSensor-L4sets Measurement under all same conditions
Interface for external storage mediumPort for USB2.0 flash memory (*2)
Other FunctionsAlarm by buzzer when over target OD and activate pump (option)
Dimensions153 x 220 x 127Hmm
(*1)Point = Total measurement time / Interval. The 360th point figure is to updated when it exceed 360 points.
(*2)Some memory cannot be used with this unit even if it can be used with a personal computer.
●The design and specifications are subject to change.
ModelODSensor-L
Measurement MethodHybrid OD, infrared light
Measurement Wavelength950nm
ConnectionOne set (use attached 0.5m flat cable )
Power SupplySupplied from ODBox-B (option)
Standard AccessoryFlat cable (2m) x 1
●The design and specifications are subject to change.

Accessories

Clamp | CF-1000
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:1L Erlenmeyer flask ■Standa ...
Clamp | CF-2000
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:2L Erlenmeyer flask ■Standa ...
Clamp | CF-3000
Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack
■Application Container:3L Erlenmeyer's flask ■Stan ...
Universal shaking platform | MT-2925
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:290 x 250 x 23Hmm ■Weight:Approx. 0.9k ...
Universal shaking platform | MT-4030
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:400 x 300 x 23Hmm ■Weight:Approx.1.4Kg
Universal shaking platform | MT-7050
It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.
■Dimensions:700 x 500 x 22Hmm ■Weight:Approx. 6Kg
Flat cable(2m) | OD-CAV0200
Connecting cable between ODBox and ODSensor
■: ■:
Color cap & tag | OD-CAP0408
Cable tag for identifying each sensor
■: ■:
Automatic pump unit | APU-01
Automatic addition of reagent at set OD, max. 4 sets are connectable.
■: ■:

Related Products

Non-contact turbidimeter for Shaking culture | OD-Monitor | OD-Monitor A&S
Measuring OD untouched flasks while cultivating as usual!!
■Component Unit:Control unit :ODBox-AMeasurement unit :ODSensor-S ■Temperature range of measurement:+15ºC - +50ºC(Be careful of setting temperature of bio shaker.)
Non-contact turbidimeter for Shaking culture | OD-Monitor | OD-Monitor C&T
The turbidity can be measured at OD600 noncontact while shaking. For test tubes.
■Component Unit:Control unit :ODBox-CMeasurement unit :ODSensor-T ■Temperature range of measurement:+15ºC - +50ºC(Be careful of setting temperature of bio shaker.)
Non-contact turbidimeter for Shaking culture | OD-Monitor control unit | ODBox-B
It is a control unit of OD-MonitorB & L.
■Display of (OD) value:Display of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria ■Measurement Range:0.1 - 9.9(accuracy guarantee range 0.3 - 7.0)
Non-contact turbidimeter for Shaking culture | OD-Monitor measurement unit | ODSensor-L
It is a measurement unit of OD-Monitor B & L.
■Measurement Method:Hybrid OD, infrared light ■Measurement Wavelength:950nm
Small size constant temperature incubator shaker | Bioshaker | BR-22FP-MR
Small type of combined usability and space-saving Those which have cooling system are equipped with environmental friendly Peltier device.
■Temperature Range:+15ºC - +60ºC (Low - middle temperature)(*1) ■Shaking Method:Rotating
Small size constant temperature incubator shaker | Bioshaker | BR-23FP-MR
Small type of combined usability and space-saving Those which have cooling system are equipped with environmental friendly Peltier device.
■Temperature Range:+15ºC - +60ºC (Low - middle temperature)(*1) ■Shaking Method:Switch rotating / reciprocal
Small size constant temperature incubator shaker | Bioshaker | BR-22UM-MR
Small type of combined usability and space-saving
■Temperature Range:RT+5ºC - +70ºC (Middle temperature) ■Shaking Method:Rotating
Small size constant temperature incubator shaker | Bioshaker | BR-23UM-MR
Small type of combined usability and space-saving
■Temperature Range:RT+5ºC - +70ºC (Middle temperature) ■Shaking Method:Switch rotating / reciprocal
Small size constant temperature incubator shaker | Bioshaker | BR-22FH-MR
Small type of combined usability and space-saving
■Temperature Range:RT +5ºC - +100ºC (Middle - high temperature) ■Shaking Method:Rotating
Small size constant temperature incubator shaker | Bioshaker | BR-23FH-MR
Small type of combined usability and space-saving
■Temperature Range:RT+5ºC - +100ºC (Middle - high temperature) ■Shaking Method:Switch rotating / reciprocal
Medium size constant temperature incubator shaker | Bioshaker | BR-40LF
Well achieved middle size. Long selling clear hood type. Space saving by stacking.
■Temperature Range:+4ºC - +70ºC (Low - middle temperature) ■Shaking Method:Switch rotating / reciprocal
Medium size constant temperature incubator shaker | Bioshaker | BR-42FL-MR
Well achieved middle size. Left-right opening door type. Both are space saving by stacking.
■Temperature Range:+4ºC - +70ºC (Low - middle temperature) ■Shaking Method:Rotating
Medium size constant temperature incubator shaker | Bioshaker | BR-43FL-MR
Well achieved middle size. Left-right opening door type. Both are space saving by stacking.
■Temperature Range:+4ºC - +70ºC (Low - middle temperature) ■Shaking Method:Switch rotating /reciprocal
Medium size constant temperature incubator shaker | Bioshaker | BR-42FM-MR
Well achieved middle size. Left-right opening door type. Both are space saving by stacking.
■Temperature Range:RT+5ºC - +70ºC (Middle temperature) ■Shaking Method:Rotating
Medium size constant temperature incubator shaker | Bioshaker | BR-43FM-MR
Well achieved middle size. Left-right opening door type. Both are space saving by stacking.
■Temperature Range:RT+5ºC - +70ºC(Middle temperature) ■Shaking Method:Switch rotating / reciprocal
Medium size constant temperature incubator shaker | Bioshaker | BR-43FH-MR
Well achieved middle size. Left-right opening door type. Both are space saving by stacking.
■Temperature Range:RT+5ºC - +100ºC (Middle - high temperature) ■Shaking Method:Switch rotating / reciprocal
Medium size constant temperature incubator shaker | Bioshaker | BR-53FP
Peltier cooling with CFC-free. Temperature range ensures 15℃ to 55℃. Cut power consumption by 80% with the conventional one.
■Temperature range (*1):15℃ to 55℃ ■Shaking motion:Switchable Reciprocal/Orbital shaking
Large size constant temperature incubator shaker | Bioshaker | GBR-200
Save your space with lift-up door and stackable, enable to use as laboratory table, culture large capacity
■Temperature Range:+4ºC - +80ºC ■Temp. Control Accuracy:±0.3ºC - 1.0ºC (*1)
Large size constant temperature incubator shaker | Bioshaker | GBR-300
Save your space with lift-up door and stackable, enable to use as laboratory table, culture large capacity
■Temperature Range:+4ºC - +80ºC ■Temp. Control Accuracy:±0.3ºC - 1.0ºC (*1)
Large size constant temperature incubator shaker | Bioshaker | BR-180LF
Split doors enables easier access to large container. Movable with wheels.
■Temperature Range:+4ºC - +70ºC ■Temp. Control Accuracy:±0.3ºC - 1.0ºC(*1)
Large size constant temperature incubator shaker | Bioshaker | BR-300LF
Long selling large type with variable shaking amplitude.
■Temperature Range:+4ºC - +70ºC ■Temp. Control Accuracy:±0.3ºC - 1.0ºC (*1)
Non-contact turbidimeter for Shaking culture | | OD-Monitor Turbidostat System A
Enables Continuous culture with OD-Monitor. Fluid volume: 20/40/60/100mL.
■Measurement method:Light transmission ■Measurement range:OD600=0.00~2.55
Non-contact turbidimeter for Shaking culture | | OD-Monitor Turbidostat System B
Enables Continuous culture with OD-Monitor. Fluid volume: 350/700/1000mL.
■Measurement method:Light transmission/Reflected light ■Measurement range:OD600=0.00~9.99
Translate »