e-TAITEC.com

Product Info

Unit water bath

Thermominder SDN

Code No.: 0072373-000

Addressed to low water of 45mm to fit to micro tube and small test tube. Optimum for examination.


Applications

Various incubation such as enzyme reaction
Inactivation of serum and thermal insulation of culture medium
Hybridization

Features


Specifications

ModelSDN
Temperature RangeRT+5ºC - +70 ºC
Temperature setting-20℃ - +100℃ (*1)
Temp. Control Accuracy±0.1℃ - 0.3 ºC
Minimum temperature setting unit0.1ºC (setting and display)
FlowJet blast
Temperature DisplayDigital display
Setting temperature (top panel) and inside chamber temperature (side panel)
Memorythree memory
Heater800W
WeightApprox. 3kg (when using thermal insulation tray B: Approx. 6kg)
Safety device / functionCircuit protector (15A), fuse (2A), float type prohibition of boiling while empty
Misalignment high and low temperature error , lowing water, sensor error, auto tuning error, non-volatile storage error
Dimensions280 x 109 x 215Hmm
(when using thermal insulation tray B: 280 x 475 x 240Hmm)
Power SupplyAC100V/8.5A (Need a step-down transformer)
(*1) Cooling machine such as "Cool pipe" is required for set below environmental temperature. Antifreezing solution is required for set below +7℃.
(*2) This production is specialized for thermal insulation tray B (inner Dimensions 235 x 430 x 140Hmm). Other water bath cannot be used.

Accessories

Heat-resistant plastic hood | PF-B
Preventing evaporation.
■: ■:
Thermal insulation bath type-B | Thermal insulation bath B-type
Same model with one attached to thermominder SDN/EXN-B.
■: ■:

Related Products

Unit water bath | Thermominder | SDminiN
Even water level of 45 mm from the bottom of the bath can be used. With the included Plastic Water bath, it is easy to use. The Optional Thermal insulation Water bath can be combined.
■Temperature range (*1):+5℃ above RT to +80℃ (*2) ■Settable temp. range (*3):-20℃ to +80℃
Unit water bath | Thermominder | EXN-B
Addressed to low water of 45mm to fit to micro tube and small test tube. Optimum for examination.
■Temperature Range:RT+5ºC - +70 ºC ■Temperature setting:-20℃ - +100℃ (*1)
Unit water bath | Thermominder | SM-05N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model.
■Temperature range (*1):5℃ above RT to +85℃ ■Settable temp. range (*2):-20℃ to +85℃
Unit water bath | Thermominder | SJ-07N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +95℃ ■Settable temp. range (*2):-20℃ to +95℃
Unit water bath | Thermominder | SX-10N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +105℃ ■Settable temp. range (*2):-20℃ to +105℃
Unit water bath | Thermominder | SH-10N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +180℃ ■Settable temp. range (*2):-20℃ to +180℃
Unit water bath | Thermominder | SP-12N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +100℃ ■Settable temp. range (*2):-20℃ to +100℃
Automatic water supply Unit | Level keeper | UB-2
No risk of boil with no water while operating for long period.
■Max. Operable differential pressure:Below 1.0 MPa (10 kg/cm2) ■Heat-resistant temp.:-10 to +70℃ (Water supply temp. Up to +40℃)
Immersion cooler | Cool pipe | 80LF
Easy to insert the tip of the cooling pipe in the object for use. For making the Thermominder, a Low temp. constant bath and Cooling for trapping vessels for Concentrator.
■Temperature range (*1):-10℃ to +30℃ ■Cooling capacity (*2):Approx. 150 W
Immersion cooler | Cool pipe | 150LF
Easy to insert the tip of the cooling pipe in the object for use. For making the Thermominder, a Low temp. constant bath and Cooling for trapping vessels for Concentrator.
■Temperature range (*1):-15℃ to +30℃ ■Cooling capacity (*2):Approx. 290 W
Bench-top shaking water bath | shaking water bath | Personal-11 SDN Set
Standard shaking water bath for personal use. Set of Personal-11 and Thermominder SDN.
■Product contents:Thermoregulation part:SDNShaker part:Personal-11 ■Dimensions:300 x 495 x 336Hmm
Bench-top shaking water bath | Shaking water bath | Personal Monode SDN Set
Versatile Bench-top Water bath that is equipped with Reciprocal shaking. Unique Monode shaking platform for shaking L-shaped test tubes is available as an option.
■Temperature range (*2)(Thermominder):5℃ above RT to +70℃ (Preset/Current temp. displayed simultaneously in the SDN/EXN switch. Switchable Preset/Current temp display in SM.) ■Temp. control accuracy (*3)(Thermominder):±0.1℃ to 0.3℃