e-TAITEC.com

Product Info

Unit water bath

Thermominder SDN-B

Code No.: 0072373-000

Even water level of 45 mm from the bottom of the bath can be used. Thermal insulation tray is included. The EXN-B is equipped with Temp. control accuracy with two decimal places and a Timer function.

Image of using thermal insulation tray B (attached)

Applications

Various incubations such as Enzyme reaction
Temporarily Incubation of Culture medium
Inactivation of Serum

Down Load(Useful Information)

General Catalog

Features

Addressed low water level (45mm) enables safety thermal insulation of container
Using at low temperature level is optimum for small container such as micro tube. There is no risk of turning over test tube which has low level of content since tube is not floating.

Safe working even at low water level



Temperature setting using Up-Down key.
Up-Down key can set temperature in unit of 0.1ºC. Setting temperature and actual temperature are digital display.
SDN-B can memorize three temperature settings.
SDN-B can memorize three temperature settings.
Becomes moist chamber using heat-proof plastic hood
With optional heat-proof plastic hood RF-SDM, take advantage of addressing low water level by speeding up temperature rise by 10 min and preventing evaporation. Furthermore it can be used as moist chamber which is useful for in situ hybridization.
Machine body and wetted surface material is stainless steel
This machine is durable and easy to maintain hygienically because machine body (except float switch) and wetted surface of attached thermal insulation tray B is made of stainless steel.
Two types of different temperature regulation accuracy and with or without timer
There are two models; standard model of SDN-B and EXN-B with higher accurate temperature regulation by one digit and has ON-OFF timer. They are specialized thermo minder for attached thermal insulation tray B and shaking water bath personal .

Specifications

ModelSDN-B
Temperature range (*1)5℃ above RT to +70℃
Settable temp. range (*2)-20℃ to +100℃
Temp. control accuracy (*3)±0.1℃ to ±0.3℃
Stirring method in BathJet flow
FlowJet blast
Temperature display/Temperature memoryDisplay: Digital (Changeable Preset/Current value)Memory: 3
Other functionsBuzzer notification when Preset temp. is reached
Automatic tuning
Minimum Water level45 mm from the bottom of the bath
Heater800 W
Safe devices/protectionsCircuit protector, Fuse, Dry-heating protection with float, Sensor error, Short circuit, High/Low temp. sample protection, Water level alarm, Non-volatile memory error,
Automatic tuning error, Alarm setting error
Power failureSwitchable Automatic/Manual recovery
Dimensions inside Bath(W×D×H)230 × 350 × 140 mm
Main unit dimensions(W×D×H)280 × 109 × 215 mm (When Thermal insulation tray B-type is used: 280 × 475 × 240 mm)
WeightApprox. 3 kg (6 kg: Thermal insulation tray B-type is included)
Power supply/consumptionAC100V/8.5A (Need a step-down transformer), 105 Wh at 37℃
Standard accessoriesThermal insulation bath B-type × 1 pc (*5)
(*1)Max. temp. may not be reached when the optional Hood is not used or depending on the usage conditions.As it is dangerous due to steam when using high temp. with tap water, it is recommended to use our specified Heat medium for High temp.
(*2)Not equipped with a cooling function. Can be used together with our Chiller/Coolnit, Immersion cooler, etc. at below RT (25℃). Use our specified Antifreeze fluid when preset temp. is below 7℃. The usage life of the components may be shortened when used at the upper limit temp.
(*3)The value under the conditions of RT (25℃), AC100 V/50 Hz, Capacity 6 liters water, Preset temp. 37℃, and No heat load
with Thermal insulation tray B-type. For EXN-B, this is an actual measured value (0.01 unit).
(*4)Optional Signal cable CA-671 is required to output. Ask us for the Temperature Input.
(*5)Thermal insulation bath B-type is sold separately.

Dimensions

Accessories

Heat-resistant plastic hood | PF-B
Preventing evaporation.
■: ■:
Thermal insulation bath type-B | Thermal insulation bath B-type
Same model with one attached to thermominder SDN/EXN-B.
■: ■:

Related Products

Unit water bath | Thermominder | SDminiN
Even water level of 45 mm from the bottom of the bath can be used. With the included Plastic Water bath, it is easy to use. The Optional Thermal insulation Water bath can be combined.
■Temperature range (*1):+5℃ above RT to +80℃ (*2) ■Settable temp. range (*3):-20℃ to +80℃
Unit water bath | Thermominder | EXN-B
Addressed to low water of 45mm to fit to micro tube and small test tube. Optimum for examination.
■Temperature Range:RT+5ºC - +70 ºC ■Temperature setting:-20℃ - +100℃ (*1)
Unit water bath | Thermominder | SM-05N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model.
■Temperature range (*1):5℃ above RT to +85℃ ■Settable temp. range (*2):-20℃ to +85℃
Unit water bath | Thermominder | SJ-07N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +95℃ ■Settable temp. range (*2):-20℃ to +95℃
Unit water bath | Thermominder | SX-10N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +105℃ ■Settable temp. range (*2):-20℃ to +105℃
Unit water bath | Thermominder | SH-10N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +180℃ ■Settable temp. range (*2):-20℃ to +180℃
Unit water bath | Thermominder | SP-12N
Five models: Economy, Standard, High Specs, High Temp., and External Circulation. Select the most suitable model according to your purpose. Each Power consumption example is described for each model (See below).
■Temperature range (*1):5℃ above RT to +100℃ ■Settable temp. range (*2):-20℃ to +100℃
Automatic water supply Unit | Level keeper | UB-2
No risk of boil with no water while operating for long period.
■Max. Operable differential pressure:Below 1.0 MPa (10 kg/cm2) ■Heat-resistant temp.:-10 to +70℃ (Water supply temp. Up to +40℃)
Immersion cooler | Cool pipe | 80LF
Easy to insert the tip of the cooling pipe in the object for use. For making the Thermominder, a Low temp. constant bath and Cooling for trapping vessels for Concentrator.
■Temperature range (*1):-10℃ to +30℃ ■Cooling capacity (*2):Approx. 150 W
Immersion cooler | Cool pipe | 150LF
Easy to insert the tip of the cooling pipe in the object for use. For making the Thermominder, a Low temp. constant bath and Cooling for trapping vessels for Concentrator.
■Temperature range (*1):-15℃ to +30℃ ■Cooling capacity (*2):Approx. 290 W
Bench-top shaking water bath | shaking water bath | Personal-11 SDN Set
Standard shaking water bath for personal use. Set of Personal-11 and Thermominder SDN.
■Product contents:Thermoregulation part:SDNShaker part:Personal-11 ■Dimensions:300 x 495 x 336Hmm
Bench-top shaking water bath | Shaking water bath | Personal Monode SDN Set
Versatile Bench-top Water bath that is equipped with Reciprocal shaking. Unique Monode shaking platform for shaking L-shaped test tubes is available as an option.
■Temperature range (*2)(Thermominder):5℃ above RT to +70℃ (Preset/Current temp. displayed simultaneously in the SDN/EXN switch. Switchable Preset/Current temp display in SM.) ■Temp. control accuracy (*3)(Thermominder):±0.1℃ to 0.3℃
Translate »